Patient-specific hemodynamic evaluation of fenestrated physician-modified endografts in complex abdominal aortic aneurysms
Xiaolong Du, Shichen Jiang, Hongyue Zhang, Huiying Yu, Li Zhang, Kai Ren, Feng Ran
Nanjing University of Chinese Medicine · Nanjing Forestry University
Key points
From the paper's conclusion- Purpose Physician-modified endografts (PMEGs) are increasingly used for complex abdominal aortic aneurysms (AAA), but the patient-specific flow consequences of the geometric reconstruction are not well quantified.
Abstract
Purpose Physician-modified endografts (PMEGs) are increasingly used for complex abdominal aortic aneurysms (AAA), but the patient-specific flow consequences of the geometric reconstruction are not well quantified. This study evaluated PMEG-associated changes in hemodynamic and wall-mechanical surrogate markers. Materials and Methods Eight patients were retrospectively analyzed. Pre- and post-PMEG geometries were reconstructed from computed tomography angiography and simulated with pulsatile computational fluid dynamics under matched inlet and outlet conditions. Time-averaged wall shear stress relative residence time and endothelial cell activation potential were quantified; one representative case underwent fluid-structure interaction analysis. Results Mean velocity increased from approximately 0.8–1.5 m/s ( P = 0.0021), pressure drop decreased ( P = 0.0183), low-shear regions became less extensive, and RRT and ECAP decreased significantly (both P < 0.05). FSI showed lower computed wall deformation after repair. At 1 year, all branch stents remained patent, with no endoleak or reported adverse event. Conclusion Together with prior paired PMEG simulations, these findings support a favorable hemodynamic and wall-mechanical effect of PMEG in complex anatomy unsuitable for conventional infrarenal EVAR and suggest a less stasis-prone postoperative environment. Larger controlled cohorts remain necessary to determine whether these surrogate changes translate into fewer clinical thrombotic or rupture events. The observed changes arise from PMEG-induced geometric remodeling, which modifies local flow acceleration, separation, near-wall shear, and pressure-loss characteristics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physician-modified endografts using an endoskeleton ePTFE platform for complex aortic aneurysms requiring a single fenestration: a proof-of-concept study.CVIR endovascular · 2026
- Using patient-specific computational fluid dynamics to assess intraprosthetic thrombus formation risk and guide relining after endovascular aneurysm repair.JVS-vascular science · 2026
- Outcomes of Physician-Modified Endografts for Juxtarenal and Pararenal Abdominal Aortic Aneurysms: A Systematic Review and Single-Arm Meta-Analysis.Journal of clinical medicine · 2026
- Hemodynamic Effects of Renal Artery Orientation and Partial Ostial Coverage After Endovascular Aneurysm Repair: A 4D Flow MRI-Informed Computational Study.Bioengineering (Basel, Switzerland) · 2026
- Endovascular aortic repair for abdominal aortic aneurysm with horseshoe kidney using a physician-modified endograft to preserve an accessory renal artery.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026
- Impact of stent graft geometry on hemodynamics in superior mesenteric artery reconstruction after fenestrated/branched endovascular aneurysm repair.Frontiers in bioengineering and biotechnology · 2026