Dosimetric Vulnerability of Radiotherapy Techniques Under Non-Rigid Arm-Position-Induced Deformations in Breast Cancer: A Deformable Phantom Study
So Hyun Park, Jinhyun Choi
Key points
From the paper's conclusion- We developed a breast-mimicking rubber and silicone phantom to evaluate dosimetric effects of arm-position-induced deformation in three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT).
Abstract
Accurate positioning is essential in breast radiotherapy; however, rigid phantoms do not reproduce posture-related anatomical deformation. We developed a breast-mimicking rubber and silicone phantom to evaluate dosimetric effects of arm-position-induced deformation in three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT). The phantom included a central internal marker and five surface optically stimulated luminescence dosimeter attachment points. Treatment plans were generated from computed tomography images to deliver 42.4 Gy in 16 fractions. Surface doses were measured with a linear accelerator in reference and modified arm-shift postures. 3D-CRT showed differences below 1.00% at nearly all points and a maximum deviation of −0.77% laterally. IMRT showed greater sensitivity, reaching 2.53% at the lower point. VMAT showed the largest changes: a 21.19% dose deficit (0.414 Gy) at the lower point and a −5.88% difference laterally. Arm position changes therefore produced localized surface-dose variation, particularly in the lower breast. These findings highlight the importance of careful arm positioning and reproducible setup when highly modulated techniques are used and suggest that deformable phantoms can complement conventional rigid quality-assurance tools. Under these experimental conditions, VMAT was more sensitive than IMRT and 3D-CRT at selected surface measurement points in this phantom model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Maintaining setup reproducibility in patients unable to achieve bilateral arm abduction during breast radiotherapy: evaluation of a novel arm support deviceJournal of Radiotherapy in Practice · 2026
- Strategic planning approaches to optimize volumetric modulated arc therapy for locoregional breast irradiation.Radiation and environmental biophysics · 2026
- Manufacturing and effectiveness evaluation of effective breast suit for breast radiotherapyOSF Preprints (OSF Preprints) · 2026
- ExacTrac Dynamic Surface-Guided Setup Versus Tattoo-Based Positioning in Breast Cancer Radiotherapy: A Retrospective Comparison of Setup Accuracy and Preparation Time.Cancers · 2026
- Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
- Comparative Analysis of Arc Geometrical Configurations and Jaw Tracking for Peripheral Low-Dose Bath in Whole Breast VMAT.Technology in cancer research & treatment · 2026