Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator.
Yara G Farid, Mohamed S Ibrahim, Medhat W Shafaa, Noha A Rahmoun, Magdy M Khalil, Khalid A Khalil
Medical Biophysics, Department of Physics, Faculty of Science, Helwan University, Cairo, Egypt. · Medical Physics Department, Maadi Military Hospital and Air Force Specialized Hospital, Cairo, Egypt.
Key points
From the paper's conclusion- VMAT offers superior target conformity and cardiac sparing specifically for the LAD, whereas 3DCRT minimises contralateral organs and low-dose lung exposure. These findings highlight the necessity for personalised treatment, whether the priority is to limit cardiac toxicity or reduce low-dose exposure to the patient.
Abstract
BACKGROUND: To identify the optimal radiotherapy planning technique that provides the best dosimetric outcomes in terms of target coverage and sparing of organs at risk (OAR) when using deep inspiration breath-holding (DIBH) for early left-sided breast cancer treatment. MATERIALS AND METHODS: Thirty patients with early-stage left-sided BC had previously been simulated and treated with DIBH using the active breathing coordinator (ABC) system. Each patient underwent replanning using 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) techniques with a prescription dose of 40.05 Gy over 15 fractions. The planning target volume (PTV) and OARs were evaluated using dose-volume histograms (DVH). Dosimetric parameters [V95, D98, D50, D2, V107, conformity index (CI), homogeneity index (HI)], and OAR metrics for the heart, left anterior descending artery (LAD), lungs, and contralateral breast were analysed statistically. RESULTS: VMAT achieved the best PTV coverage and homogeneity (HI = 0.1). The mean heart dose was lowest for 3DCRT (1.9 Gy) and VMAT (2 Gy), whereas for the LAD VMAT achieved the lowest doses (Dmean = 5.2 Gy; Dmax = 17.3 Gy; p < 0.001). For the ipsilateral lung, 3DCRT offered superior low-dose sparing, while VMAT minimised high-dose exposure. Contralateral lung and breast doses were lowest with 3DCRT. CONCLUSIONS: VMAT offers superior target conformity and cardiac sparing specifically for the LAD, whereas 3DCRT minimises contralateral organs and low-dose lung exposure. These findings highlight the necessity for personalised treatment, whether the priority is to limit cardiac toxicity or reduce low-dose exposure to the patient.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dosimetric Comparison of Five Radiotherapy Techniques in Left-Sided Breast Cancer Patients Following Breast-Conserving Surgery.The breast journal · 2026
- Comparison of heart-sparing radiation techniques for left-sided breast cancer: DIBH combined with tangential 3D radiation vs. conventional and tangential VMAT techniquesRadiation Oncology · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Dosimetric comparison of organs at risk exposure in multicatheter high-dose-rate interstitial brachytherapy vs. VMAT-based APBI for real patient treatment plans.Journal of contemporary brachytherapy · 2026
- Dosimetric benefits of deep inspiration breath-hold in postoperative radiotherapy for left-sided breast cancer after breast-conserving surgery: an anatomical parameter-based analysis.Frontiers in oncology · 2026
- Strategic planning approaches to optimize volumetric modulated arc therapy for locoregional breast irradiation.Radiation and environmental biophysics · 2026