From the paper's conclusion
  • VMAT offers superior target conformity and cardiac sparing specifically for the LAD, whereas 3DCRT minimises contralateral organs and low-dose lung exposure. These findings highlight the necessity for personalised treatment, whether the priority is to limit cardiac toxicity or reduce low-dose exposure to the patient.

Abstract

BACKGROUND: To identify the optimal radiotherapy planning technique that provides the best dosimetric outcomes in terms of target coverage and sparing of organs at risk (OAR) when using deep inspiration breath-holding (DIBH) for early left-sided breast cancer treatment. MATERIALS AND METHODS: Thirty patients with early-stage left-sided BC had previously been simulated and treated with DIBH using the active breathing coordinator (ABC) system. Each patient underwent replanning using 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) techniques with a prescription dose of 40.05 Gy over 15 fractions. The planning target volume (PTV) and OARs were evaluated using dose-volume histograms (DVH). Dosimetric parameters [V95, D98, D50, D2, V107, conformity index (CI), homogeneity index (HI)], and OAR metrics for the heart, left anterior descending artery (LAD), lungs, and contralateral breast were analysed statistically. RESULTS: VMAT achieved the best PTV coverage and homogeneity (HI = 0.1). The mean heart dose was lowest for 3DCRT (1.9 Gy) and VMAT (2 Gy), whereas for the LAD VMAT achieved the lowest doses (Dmean = 5.2 Gy; Dmax = 17.3 Gy; p < 0.001). For the ipsilateral lung, 3DCRT offered superior low-dose sparing, while VMAT minimised high-dose exposure. Contralateral lung and breast doses were lowest with 3DCRT. CONCLUSIONS: VMAT offers superior target conformity and cardiac sparing specifically for the LAD, whereas 3DCRT minimises contralateral organs and low-dose lung exposure. These findings highlight the necessity for personalised treatment, whether the priority is to limit cardiac toxicity or reduce low-dose exposure to the patient.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers