Technology in cancer research & treatment

Comparative Analysis of Arc Geometrical Configurations and Jaw Tracking for Peripheral Low-Dose Bath in Whole Breast VMAT.

Chanyoung Park, Jun-Bong Shin, Semie Hong, Jeong-Woo Lee

Department of Medical Physics Convergence, Konkuk University, Seoul, Republic of Korea. · Department of Radiation Oncology, Kangwon National University Hospital, Gangwon-do, Republic of Korea.

Observational

Key points

From the paper's conclusion
  • This study compared the dosimetric impact of arc geometry and jaw tracking under controlled planning conditions to characterize their effects on low-dose exposure.MethodsIn this retrospective dosimetric study, VMAT plans were generated for 30 breast cancer patients (15 left-sided and 15 right-sided).

Abstract

IntroductionMinimizing low-dose radiation spillage to surrounding organs at risk (OARs) is a critical consideration in whole breast irradiation (WBI) using volumetric modulated arc therapy (VMAT). While VMAT improves dose conformity and delivery efficiency, its continuous arc delivery may increase the "low-dose bath" in normal tissues. This study compared the dosimetric impact of arc geometry and jaw tracking under controlled planning conditions to characterize their effects on low-dose exposure.MethodsIn this retrospective dosimetric study, VMAT plans were generated for 30 breast cancer patients (15 left-sided and 15 right-sided). Four arc configurations were evaluated: conventional-arc VMAT (two and four arcs), tangential-arc VMAT (TA-VMAT), and hybrid-arc VMAT (HA-VMAT). Each configuration was planned with and without jaw tracking using identical objectives. Dose-volume histogram (DVH) parameters were analyzed for the planning target volume (PTV) and OARs, including the ipsilateral/contralateral lungs, heart, left anterior descending coronary artery (LAD), liver, and contralateral breast.ResultsAll techniques achieved comparable target coverage. Arc configuration substantially affected OAR dose distribution. Compared with conventional-arc VMAT, TA-VMAT reduced contralateral lung and breast exposure by 60-70%, while HA-VMAT yielded intermediate results. Notably, tangential arc restriction increased ipsilateral lung dose, particularly in right-sided cases, and increased LAD dose in left-sided cases. Jaw tracking provided additional dose reductions in selected OAR metrics, although the magnitude and statistical significance of these changes varied across arc configurations.ConclusionsThe findings suggest that peripheral low-dose exposure in whole-breast VMAT is influenced by arc configuration, while jaw tracking may provide additional dose reduction in selected OAR metrics. Considering both beam geometry and delivery-level leakage control may help reduce unnecessary OAR exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers