Radiation and environmental biophysics

Strategic planning approaches to optimize volumetric modulated arc therapy for locoregional breast irradiation.

Mahmoud Alfishawy, Tauseef Ali, Muhsina Vellengara, Iqbal Al Amri, Zahid Al-Mandhari, Ana Paula Galerani Lopes

Sultan Qaboos Comprehensive Cancer Care and Research Centre, University Medical City, Muscat, Oman. m_alfishawy@yahoo.com. · Sultan Qaboos Comprehensive Cancer Care and Research Centre, University Medical City, Muscat, Oman.

Key points

From the paper's conclusion
  • It is concluded that the optimized VMAT technique provided high target coverage, dose conformity, and OAR sparing, supporting its suitability for locoregional breast cancer radiotherapy.

Abstract

This study aimed to evaluate an optimized volumetric modulated arc therapy (VMAT) approach for locoregional breast cancer cases requiring regional nodal irradiation, including the internal mammary node (IMN), axillary, and supraclavicular lymph nodes (Node). A total of 139 patients treated between January 2024 and January 2025 were prescribed to 40 Gy in 15 fractions, with 37 cases had a simultaneous integrated boost (SIB) to 48 Gy. The optimized VMAT incorporated breast flash, moderate Aperture Shape Controller settings, arm entry beam avoidance, specialized optimization structures, and limited gantry rotation to enhance plan efficiency and deliverability. In SIB patients, median planning target volume (PTV) coverage for boost volume at V50.4 Gy (volume receiving 50.4 Gy) and V45.6 Gy was 4.7% and 98.2%, respectively. For remaining targets, coverage was PTV-Breast V38Gy was 97.4%, PTV-Node V38Gy was 97.1%, and PTV-IMN V34Gy was 98.4%. In non-SIB cases, PTV-Breast V42.8 Gy and V38Gy were 1.5% and 96.7%, respectively PTV-Node V42.8 Gy and V38Gy were 0.2% and 97.6%, respectively, and PTV-IMN V34Gy was 99.5%. Regarding organs at risk (OARs), median doses to the ipsilateral lung, contralateral lung, total lung, and contralateral breast were 10.6, 2.0, 6.5, and 3.3 Gy, respectively, while the median heart dose was 4.1 Gy for left-sided versus 3.0 Gy for right-sided cases. Volume-based metrics showed heart V4Gy of 24.3% and V25Gy of 0.03%; ipsilateral lung V5Gy of 52.5%, V10Gy of 34.0%, and V20Gy of 20.9%; contralateral lung V5Gy of 6.7%; and contralateral breast V5Gy of 17.9%. It is concluded that the optimized VMAT technique provided high target coverage, dose conformity, and OAR sparing, supporting its suitability for locoregional breast cancer radiotherapy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers