Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance.
Doyeon Kim, Seung Pil Bang
Department of Medicine, Keimyung University School of Medicine, Daegu 42601, Republic of Korea. · Department of Ophthalmology, Keimyung University School of Medicine, Daegu 42601, Republic of Korea.
Key points
From the paper's conclusion- This narrative review summarizes the optical principles of Scheimpflug imaging and AS-OCT, synthesizes the available comparative literature, and analyzes the mechanisms that may contribute to inter-device discordance, including differences in light sources and light-tissue interactions, posterior-surface reconstruction and refractive-index assumptions, edge-detection and Zernike-fitting algorithms
Abstract
Total corneal aberration analysis is increasingly used as part of intraocular lens selection, ectasia screening, and refractive surgery planning. Scheimpflug-based tomography and anterior segment optical coherence tomography (AS-OCT) are commonly used imaging techniques to identify the anterior and posterior corneal surfaces; however, many devices combine these methods with Placido-disc topography or reconstruction algorithms. Although these devices provide anterior, posterior, and total corneal wavefront aberrations, multiple studies have shown that Zernike coefficients obtained with different systems are not consistently interchangeable, particularly for posterior-surface-derived and higher-order terms such as trefoil and total higher-order aberration root-mean-square values. This narrative review summarizes the optical principles of Scheimpflug imaging and AS-OCT, synthesizes the available comparative literature, and analyzes the mechanisms that may contribute to inter-device discordance, including differences in light sources and light-tissue interactions, posterior-surface reconstruction and refractive-index assumptions, edge-detection and Zernike-fitting algorithms, sampling geometry and acquisition time, and reference-axis selection. We discuss the clinical implications of these discrepancies and propose a research agenda, including model-eye validation and ray-tracing simulation studies, to help distinguish the effects of hardware optics from those of proprietary reconstruction algorithms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concordance of Corneal Tomographic Measurements Obtained via Swept-Source Optical Coherence Tomography Versus Scheimpflug Tomography.Bioengineering (Basel, Switzerland) · 2026
- Extending a Standard SD-OCT Device to Ocular Biometry with Additional Software: Agreement and Clinical Applicability Compared with Ultrasound and Optical Biometry.Journal of clinical medicine · 2026
- Comparison of Theoretical Impact of Lateral Translation and Cyclotorsion on Residual Aberrations in Refractive SurgeryPhotonics · 2026
- Spectrometer matching for balanced detection in spectral-domain optical coherence tomography by autocorrelation minimization.Biomedical optics express · 2026
- Agreement of corneal thickness measured by Scheimpflug, SS-OCT, and specular microscopy in Chinese myopia.BMC ophthalmology · 2026
- Repeatability, Reproducibility and Inter-Device Agreement of Anterior and Posterior Corneal Parameters Measured with Visionix 130+ and Pentacam HR in Healthy EyesPhotonics · 2026