Comparison of Theoretical Impact of Lateral Translation and Cyclotorsion on Residual Aberrations in Refractive Surgery
Samuel Arba Mosquera, Shwetabh Verma
Key points
From the paper's conclusion- Purpose: To quantitatively compare the theoretical optical effects of lateral translation and cyclotorsion on residual aberrations following refractive surgery using a common wavefront-based metric.
Abstract
Purpose: To quantitatively compare the theoretical optical effects of lateral translation and cyclotorsion on residual aberrations following refractive surgery using a common wavefront-based metric. Methods: Corneal wavefront data from 2543 eyes without previous ocular surgery were analyzed at a 6 mm pupil diameter. Zernike coefficients through the seventh radial order were transformed using an analytical framework for translated and rotated wavefronts. Lateral translation was simulated along the X-axis from −1.00 to +1.00 mm, and cyclotorsion from −15° to +15°. For each simulated condition, relative residual RMS was calculated as the residual wavefront RMS relative to the original wavefront RMS and averaged across eyes. Translation and cyclotorsion producing comparable relative residual RMS values were estimated using shape-preserving piecewise cubic Hermite interpolation. Combined translation and rotation were also evaluated. Results: Relative residual RMS increased approximately symmetrically with the magnitude of both alignment errors, with a substantially greater sensitivity to lateral translation. A relative residual RMS of 5% corresponded to approximately 0.09 mm of translation or 2.8° of cyclotorsion, whereas 25% relative residual RMS corresponded to approximately 0.42 mm or 14.1°, respectively. The translation–rotation relationship was nonlinear. When both errors were present, relative residual RMS increased with increasing magnitude of either error, while retaining greater sensitivity to translation. Conclusions: In this theoretical analysis, substantially smaller lateral translations produced relative residual RMS comparable to that produced by larger cyclotorsion errors. Expressing both errors through a common metric provides a quantitative framework for interpreting their relative optical effects. The resulting relationship represents a theoretical optical comparison and does not establish clinical alignment tolerances or equivalent visual effects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Total Corneal Aberration Measurements by Anterior Segment Optical Coherence Tomography and Scheimpflug-Based Imaging: A Narrative Review of Optical Principles and Sources of Inter-Device Discordance.Journal of clinical medicine · 2026
- Planning Adjustment of Toric Capsular Bag Intraocular Lens Axis to Minimise Refractive Cylinder Outcome—A Calculation Concept Based on Vergence TransformationsDiagnostics · 2026
- Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation.Journal of clinical medicine · 2026
- Physics-guided neural reconstruction of corneal topography from Placido-ring images.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Biconcave freeform implantable contact lenses: wide-field design and peripheral aberration optimization.Optics express · 2026
- New Asymmetric Transition Zone Centration Strategy for Refractive Corrections: Geometrical Background.Translational vision science & technology · 2026