Uncoupled Auxiliary S2-Alar-Iliac Screws in Long Lumbopelvic Constructs: Exploratory Finite Element Analysis and Preliminary Clinical Experience.
Celal Ozbek Cakir, Murat Baloglu, Ulkun Unlu Unsal, Hakan Millet, Erdal Yayla, Eser Pala, Ismail Bozkurt
Department of Neurosurgery, Afyon Park Hospital, Afyon 03100, Turkey. · Department of Neurosurgery, Eskisehir City Hospital, Eskisehir 26080, Turkey.
Key points
From the paper's conclusion- Background and Objectives: In this study, uncoupled auxiliary trans-sacroiliac (UATS) screws were evaluated as a mechanically independent adjunct to conventional S2-alar-iliac (S2AI) fixation in long lumbopelvic constructs.
Abstract
Background and Objectives: In this study, uncoupled auxiliary trans-sacroiliac (UATS) screws were evaluated as a mechanically independent adjunct to conventional S2-alar-iliac (S2AI) fixation in long lumbopelvic constructs. We assessed their exploratory biomechanical behavior and preliminary clinical feasibility. Methods: Conventional bilateral S2AI fixation and the same construct supplemented with bilateral UATS screws were compared in an exploratory finite element analysis under flexion, extension, lateral bending, and axial rotation. A retrospective clinical series of 26 patients undergoing UATS-supported lumbopelvic reconstruction was also evaluated. Results: Across the four loading modes, the UATS configuration showed lower global implant-system stress (81-92% reduction) and lower global sacral stress (43-67% reduction) within the computational model. The clinical cohort was revision dominant (25/26 patients). Mean SIJ-related pain VAS decreased from 8.0 ± 1.5 to 2.4 ± 1.0 and ODI from 68.1% ± 18.1% to 16.7% ± 8.6% at final follow-up (both p < 0.001). These clinical changes reflect the overall reconstructive procedure and cannot be attributed independently to UATS fixation. Conclusions: UATS placement was technically feasible in this small, revision-dominant cohort and altered stress distribution in an exploratory, unvalidated finite element model. The present study does not establish independent clinical efficacy or superiority over established pelvic fixation or SIJ fusion strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Comparison of Three Fixation Constructs for Tile Type C1.2 Pelvic Ring Fractures: A Finite Element AnalysisLife · 2026
- Association of S2 Alar-Iliac Versus S1-Only Fixation with Spinopelvic Mobility and Acetabular Component Orientation in Total Hip Arthroplasty: A Standing-Sitting EOS Study.Journal of clinical medicine · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Unilateral biportal endoscopy-assisted direct pars repair versus posterior lumbar interbody fusion for symptomatic lumbar spondylolysis: A retrospective cohort study.The Journal of international medical research · 2026
- Comparison of novel anterior fixation method, W-plate, versus superior parasymphyseal plating in anterior posterior compression type III pelvic ring injuries: a biomechanical study.Journal of orthopaedic trauma · 2026
- Cage-Orientation-Dependent Biomechanics of Endoscopic-Compatible Bidirectional Cortical Bone Trajectory-Modified Translaminar Facet Screw Fixation versus Bilateral Percutaneous Pedicle Screw Fixation in Osteoporotic TLIF: A Finite Element Study.Medical engineering & physics · 2026