The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation.
Eva Meixner, Sophia Albert, Bahar Cepni, David Neugebauer, Hin Hoi Lau, Julian Thater, Klaus Herfarth, Stephan Mende,
Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
Key points
From the paper's conclusion- Conclusions: The tattoo-free positioning setup for regional nodal irradiation in breast cancer patients exhibited pronounced robustness, maintaining its accuracy and reliability irrespective of patient-, tumor-, or treatment-specific variables with high clinical efficiency.
Abstract
Background/Objectives: The implementation of tattoo-free radiotherapy (RT) for breast cancer reflects an effort to mitigate the psychological distress of permanent marks through surface-guided techniques, while simultaneously evaluating its utility in meeting setup precision requirements. Methods: In this prospective trial, patients were positioned for breast cancer RT including regional nodal irradiation exclusively using surface-guided RT (SGRT). Cone-beam computed tomography (CBCT) was acquired at each fraction as the ground truth to analyze translational setup deviations. Results: A total of 457 paired SGRT-CBCT data points in 30 patients were acquired. A residual translational setup deviation of ≤6 mm was achieved in 97.6% of all fractions with a median deviation of 2 mm (range: 0-12). Neither age, comorbidities, body mass index, extent of target volumes, choice of breathing technique, nor patient-reported symptoms (pain, dermatitis, anxiety) correlated significantly with setup deviations. The median in-room positioning time was 92 s (range: 20 s-6 min and 37 s) and significantly prolonged in patients with an elevated BMI and higher grades of pain and skin dermatitis, and for chest wall irradiation. Manual assessment of the accuracy of regional nodal CTVs in each CBCT relative to the planning CT showed good-to-minor deviations in 99.7% (Level 1/2), 95.0% (Supra-/infraclavicular), and 90.8% (Internal mammary), respectively, with major deviations in only 0.3% (Level 1/2), 5.0% (Supra-/infraclavicular) and 9.2% (Internal mammary). A forward dose calculation on CBCT geometries (n = 86) revealed high median CTV dose coverage of 100.0% (range: 57.1-107.7%) of the original target dose for all lymph node levels combined. Conclusions: The tattoo-free positioning setup for regional nodal irradiation in breast cancer patients exhibited pronounced robustness, maintaining its accuracy and reliability irrespective of patient-, tumor-, or treatment-specific variables with high clinical efficiency. However, larger cohorts are required to confirm whether these parameters genuinely operate independently of setup accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ExacTrac Dynamic Surface-Guided Setup Versus Tattoo-Based Positioning in Breast Cancer Radiotherapy: A Retrospective Comparison of Setup Accuracy and Preparation Time.Cancers · 2026
- Maintaining setup reproducibility in patients unable to achieve bilateral arm abduction during breast radiotherapy: evaluation of a novel arm support deviceJournal of Radiotherapy in Practice · 2026
- Development of a Statistical Framework for Optimizing Image-Guidance Frequency in Whole-Breast Radiotherapy.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Enhancing inter-fraction set-up accuracy and margin minimization (E-SAMM): a comparison of maskless surface-guided and mask-based laser alignment positioning in pelvic radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
- Dosimetric Vulnerability of Radiotherapy Techniques Under Non-Rigid Arm-Position-Induced Deformations in Breast Cancer: A Deformable Phantom StudyRadiation · 2026
- Surface-guided versus conventional setup in rectal cancer radiotherapy: A workflow-level comparison of CBCT-Derived setup corrections.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026