Enhancing inter-fraction set-up accuracy and margin minimization (E-SAMM): a comparison of maskless surface-guided and mask-based laser alignment positioning in pelvic radiotherapy.
Pramod Kumar Gupta, Sharad Singh, Rumita Singh, Sumanta Manna, Ragul T, Ritika Ranjan, Himanshu Verma, Shweta Srivastava,
Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute, Lucknow, Uttar Pradesh, India. pkg.sgpgi@gmail.com. · Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute, Lucknow, Uttar Pradesh, India.
Key points
From the paper's conclusion- Maskless SGRT provided improved inter-fraction set-up accuracy, lower estimated PTV margin requirements based on setup deviations, and shorter set-up times compared with mask-based laser alignment for pelvic radiotherapy.
Abstract
PURPOSE: Surface-guided radiation therapy (SGRT) is a non-invasive, tattoo-less technique that enables real-time optical surface monitoring during radiotherapy. This prospective E‑SAMM study compared inter-fraction set-up accuracy, estimated PTV margin requirements derived from CBCT-based pre-correction setup deviations, and set-up time between maskless SGRT and mask-based setup in patients receiving pelvic radiotherapy. METHODS: One hundred patients with pelvic malignancies (cervical, endometrial, rectal, and prostate cancers) undergoing radical or neoadjuvant radiotherapy (45-68 Gy delivered in 25-28 fractions, five fractions per week) were prospectively enrolled. A total of 2376 fractions were analysed. Patients were randomised to either maskless SGRT with AlignRT, knee support, and intrafraction monitoring (Group A, n = 50) or six-clamp mask-based laser alignment with image-guided radiotherapy (Group B, n = 50). All patients underwent online cone-beam computed tomography (CBCT) verification on a TrueBeam SVC linear accelerator with a six-degree-of-freedom couch. Inter-fraction translational (medio-lateral [ML], cranio-caudal [CC], antero-posterior [AP]) and rotational set-up errors were derived from CBCT corrections. PTV margin estimates were calculated using the van Herk formula from CBCT-recorded pre-correction setup deviations. Statistical comparisons were performed using analysis of variance and the Mann-Whitney U test. RESULTS: SGRT demonstrated significantly improved translational accuracy in the ML (1.97 ± 1.54 mm vs 2.63 ± 2.06 mm, P = 0.03) and CC (3.13 ± 2.34 mm vs 4.03 ± 2.67 mm, P = 0.001) directions compared with mask-based alignment, whereas larger shifts were observed in the AP direction (P = 0.001). Rotational differences were not statistically significant (P = 0.14). The mean three-dimensional vector displacement was significantly lower with SGRT (1.91 ± 0.36 mm) than with mask-based positioning (2.26 ± 0.48 mm; P < 0.05). Estimated PTV margins were smaller with SGRT in all translational directions. Mean set-up time was significantly reduced with SGRT (2.51 ± 0.81 min vs 3.55 ± 0.99 min, P = 0.007). CONCLUSIONS: Maskless SGRT provided improved inter-fraction set-up accuracy, lower estimated PTV margin requirements based on setup deviations, and shorter set-up times compared with mask-based laser alignment for pelvic radiotherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface-guided versus conventional setup in rectal cancer radiotherapy: A workflow-level comparison of CBCT-Derived setup corrections.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Commissioning and clinical positioning assessment of a novel surface-guided radiation therapy (SGRT) system at a C-Arm linear accelerator.Journal of applied clinical medical physics · 2026
- A multicenter end-to-end postal audit of skin markerless surface-guided radiation therapy.Journal of applied clinical medical physics · 2026
- ExacTrac Dynamic Surface-Guided Setup Versus Tattoo-Based Positioning in Breast Cancer Radiotherapy: A Retrospective Comparison of Setup Accuracy and Preparation Time.Cancers · 2026
- Maskless head and neck radiotherapy using surface-guided radiation therapy: initial clinical feasibility of real-time setup, intrafraction monitoring, and automatic beam-hold.Journal of applied clinical medical physics · 2026
- The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation.Journal of clinical medicine · 2026