Development of a Statistical Framework for Optimizing Image-Guidance Frequency in Whole-Breast Radiotherapy.
Hayato Tsuno, Ririko Kosugi, Koji Sasaki, Hiroki Kiyohara, Yukihiko Yoshimatsu, Yasuhiro Kawashima
Gunma Prefectural College of Health Sciences, 323-1, Kamioki-machi, Maebashi, Gunma, 371-0052, Japan. · Hamamatsu University School of Medicine Hospital, 1-20-1 Handayama, Chuo-ku, Hamamatsu-shi, Hamamatsu, Shizuoka Prefecture, 431-3192, Japan.
Key points
From the paper's conclusion- This study developed a statistical framework to assess setup deviations and inform image-guidance frequency.
Methods: Couch coordinates from 35 patients (596 treatment fractions) receiving postoperative whole-breast radiotherapy were retrospectively analyzed.
Abstract
Radiation therapy after breast-conserving surgery reduces local recurrence. Three-dimensional conformal radiotherapy (3D-CRT) is widely used, although large setup errors may compromise treatment reproducibility. Frequent image guidance improves setup verification but increases imaging exposure. This study developed a statistical framework to assess setup deviations and inform image-guidance frequency. Methods: Couch coordinates from 35 patients (596 treatment fractions) receiving postoperative whole-breast radiotherapy were retrospectively analyzed. Absolute Z-coordinate deviations from the mean couch position of the first three fractions were calculated, and correlations with image-guidance corrections were assessed. Statistical thresholds were derived from cumulative distributions. Results: A positive correlation was observed between couch-coordinate deviations and image-guidance corrections (Spearman's ρ = 0.75, p < 0.05). The 95th and 99th percentile statistical thresholds for the absolute Z-coordinate deviation were 4.8 mm and 6.3 mm, respectively. Retrospective application of the proposed flowchart identified 45 fractions exceeding the P95 threshold, including 36 fractions with consecutive threshold exceedances suggesting potential systematic setup deviations. Of 596 fractions, 81 met the framework's predefined criteria for image guidance. Of 183 fractions actually imaged, 81 met these criteria and 102 did not. This classification does not establish that those sessions could safely or appropriately have been omitted. Hypothetically omitting these 102 fractions from imaging would correspond to an estimated exposure difference of 58-145 mGy per patient, depending on protocol; this was not directly measured. Conclusion: The proposed framework provides a quantitative method for evaluating setup deviations using routinely available couch-coordinate information. Patient-level bootstrap resampling demonstrated statistical stability of the thresholds within this dataset. However, the thresholds have not been calibrated against clinically meaningful geometric or dosimetric endpoints, and the safety of deferring image guidance remains unestablished. External validation and prospective assessment of treatment accuracy, dosimetric impact, and clinical outcomes are needed before implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ExacTrac Dynamic Surface-Guided Setup Versus Tattoo-Based Positioning in Breast Cancer Radiotherapy: A Retrospective Comparison of Setup Accuracy and Preparation Time.Cancers · 2026
- The Prospective SPOTLESS Trial: Setup Accuracy of Tattoo-Less Surface-Guided Breast Radiotherapy Including Regional Nodal Irradiation.Journal of clinical medicine · 2026
- Set-up accuracy in megavoltage computed tomography-guided adjuvant breast radiotherapy: An analysis of differences between automatic registration and human observers.Northern clinics of Istanbul · 2026
- Improved chest wall stability during deep-inspiration breath-hold in breast cancer radiotherapy following quality improvement initiatives.Physics and imaging in radiation oncology · 2026
- Dose-Driven Rule-Based Beam Configuration for Left-Sided Breast Fixed-Field IMRT: A Commercial TPS-Based Evaluation.Biomedical physics & engineering express · 2026
- CBCT-Guided Online Adaptive Ultrahypofractionated Whole-Breast Radiotherapy for Early-Stage Breast Cancer: Dosimetric Outcomes and Acute Toxicity.Current oncology (Toronto, Ont.) · 2026