Impulse Effective Length of Horizontal Grounding Electrodes for 220 kV Transmission Towers Under Different Soil Conditions
Hanjie Yuan, Liang Chen, Yu Deng, Yaohua Zheng, Limeng Dong, Guote Liu
Key points
From the paper's conclusion- This study used a CDEGS electromagnetic-transient model to examine the impulse effective length of a horizontal grounding electrode connected to a 220 kV cat-head transmission-tower system.
Abstract
This study used a CDEGS electromagnetic-transient model to examine the impulse effective length of a horizontal grounding electrode connected to a 220 kV cat-head transmission-tower system. The model included the tower, four foundations, two overhead ground wires, adjacent-tower paths, and a buried horizontal electrode. Effective length was defined using a 5° tangent-slope criterion applied to the impulse-grounding-resistance–length curve. For a negative-polarity impulse with a magnitude of 20 kA and an 8/20 μs waveform, the calculated effective lengths were 7.679, 16.5, and 24.985 m in homogeneous soils with resistivities of 10, 100, and 1000 Ω·m, respectively. Calculations over 20–150 kA indicated that, within the investigated cases, soil condition produced a larger variation in the shunt coefficient than current magnitude. Limited field measurements in layered soil showed a qualitatively similar diminishing-return trend, but the three tested electrode lengths were insufficient for a statistically robust three-parameter fit and were not used as a direct validation of the complete tower model. System-level calculations further indicated that increasing soil resistivity from 10 to 3000 Ω·m reduced the grounding-channel shunt coefficient and the calculated lightning withstand level for the specified line configuration. The reported effective lengths are criterion- and configuration-specific engineering estimates rather than universal design constants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transient Characteristics Analysis and Resistance Reduction Optimization of Tower Grounding Electrodes Based on Non-Uniform Transmission Line Impedance ModelEnergies · 2026
- Analysis of the Implementation of Effective Grounding in 400 kV Overhead LinesEnergies · 2026
- Optimization of lightning protection grounding devices for distribution line towers under limited construction areaJournal of Physics: Conference Series · 2026
- Analysis of grounding characteristics of single-direction extended auxiliary grounding grids for transmission towersJournal of Physics: Conference Series · 2026
- Fault Response and Spatial Grounding Current Distribution Characteristics of Multipoint-Grounded GIL-Overhead Line Hybrid Transmission Systems Under High-Resistivity Soil ConditionsProcesses · 2026
- Full-process evaluation of lightning protection for multi-circuit 10 kV distribution linesJournal of Physics: Conference Series · 2026