Freezers in Residential Buildings as a Source of Power Grid Frequency Regulation in Response to the Demand for Innovation Within the Smart City Concept: Thermal–Electric Modeling, Technical Potential and Operational Challenges
Wojciech Lewicki, Hasan Hüseyin Çoban, Federico Minelli, Panagiotis Michailidis
West Pomeranian University of Technology in Szczecin · Bartin University
Key points
From the paper's conclusion- The wide availability of domestic freezers, minimal consumer impact, and broad geographic distribution suggest that this resource represents a promising complement to existing frequency regulation assets, particularly in enhancing grid stability amid increasing renewable energy penetration.
Abstract
This study assesses the technical feasibility of utilizing aggregated domestic freezers in Turkey as a distributed resource for frequency regulation. A dynamic thermal–electrical model was developed to simulate freezer responses under frequency deviation scenarios representative of real-world grid conditions. The modeled sample of 100,000 deep freezers (80 W each) can deliver approximately 3.2 MW of instantaneous down-regulation under a 40% initial duty cycle. Extrapolating to the estimated 4.7 million eligible freezers nationwide yields a total potential headroom of roughly 150–225 MW, depending on duty-cycle assumptions. The compressor duty cycle and allowable temperature range were identified as key factors influencing both regulation capacity and endurance. Although linear reference temperature control enabled effective participation in FCR-N within the simulated timeframes, it also led to cycle synchronization and peak loads following disturbances. Implementing strategies such as randomized reconnection delays could mitigate these effects. The wide availability of domestic freezers, minimal consumer impact, and broad geographic distribution suggest that this resource represents a promising complement to existing frequency regulation assets, particularly in enhancing grid stability amid increasing renewable energy penetration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dynamic and Risk-Aware Procurement of Fast Frequency Response from Electric Vehicles and Heat PumpsarXiv · 2026
- A scenario-approach optimization with output-side uncertainty for frequency control with aggregated heat pumpsE3S Web of Conferences · 2026
- Hosting Capacity of Existing Residential Electrical Connections for Flexible Distributed Computing Under Household Electrification and Temporal Load VariabilityJAPAN ARCHITECTURAL REVIEW · 2026
- Frequency-Security-Aware Real-Time Economic Dispatch with Data Center UPS Flexibility for Inertia and Primary Frequency Response ServicesarXiv · 2026
- Feeder-Aware Service-Conditioned Flexibility of Grid-Interactive BuildingsarXiv · 2026
- Sub-Synchronous Control Interaction Risk of Large Data Center Loads: A Frequency-Scan Assessment with Cross-Model ValidationarXiv · 2026