Sterilization Effect on Axes and Distances Between Three Implants in Curved Lines When Using Two Types of Two-Piece Intra-Oral Scan Bodies: An In Vitro Study.
Ofir Rosner, Adar Polonsky Katz, Joseph Nissan, Ela Shir Aghov, Diva Lugassy, Yifat Manor, Gil Ben-Izhack
Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 6997801, Israel. · Department of Orthodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 699780, Israel.
Key points
From the paper's conclusion- Therefore, three cycles of sterilization affect axes and distances for both PEEK-Ti and Ti-Ti ISBs.
Abstract
Background: The aim of this in vitro study was to examine the effect of the sterilization process on two different two-piece intra-oral scan bodies (ISBs) using three-dimensional (3D) analysis. Methods: Two identical 3D-printed models with three analogs in positions #12, #13, and 14# were used: two-piece titanium (Ti-Ti) and two-piece poly-ether-ether-ketone (PEEK) and Ti (PEEK-Ti) ISBs. Each model was scanned once before sterilization. A laboratory scanner (LBS) produced a reference stereolithography (STL) file, followed by 30 scans with an intra-oral scanner (IOS), producing 30 STL files. Both ISBs underwent three cycles of sterilization followed by thirty scans using an IOS, producing another 30 STL files. Each STL file was superimposed on the LBS reference STL file using 3D analyzing software, and the following parameters were calculated: inter-implant distance, intra-implant distance, inter-implant angle, and intra-implant angle. The Kolmogorov-Smirnov test indicated non-normal distribution; therefore, Wilcoxon signed-rank tests and Mann-Whitney tests were performed (p < 0.05). Results: Within groups, after sterilization, the mean errors of the Ti-Ti ISB were significantly increased regarding inter-implant distance 12_13 (p < 0.05), intra-implant distance 14 (p = 0.0005), inter-implant angle 12_13 (p = 0.0005), inter-implant angle 13_14 (p = 0.001), intra-implant angle 13 (p = 0.005), and intra-implant angle 14 (p < 0.05). Within groups, after sterilization, the mean errors of the PEEK-Ti ISB were significantly increased regarding inter-implant distance 12_13, 13_14, and 12_14 (p = 0.0005), intra-implant distance 12 (p < 0.05), intra-implant distance 13 and 14 (p = 0.0005), inter-implant angle 12_13 (p = 0.0005), and inter-implant angle 13_14 (p = 0.005). Between groups, after sterilization, the mean errors for the PEEK-Ti ISB were significantly higher (p < 0.0005) regarding all parameters compared to the Ti-Ti ISB. Conclusions: Both PEEK-Ti and Ti-Ti ISBs showed significant changes in most parameters after three cycles of sterilization, with the PEEK-Ti ISB exhibiting greater changes compared to the Ti-Ti ISB. Therefore, three cycles of sterilization affect axes and distances for both PEEK-Ti and Ti-Ti ISBs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dimensional Stability of SLA 3D-Printed Surgical Guide Resin After Steam Sterilization (121 °C and 134 °C) and Isopropyl Alcohol Disinfection: An In Vitro StudyDentistry Journal · 2026
- Effect of Scan Body Splinting on Geometric Scan-Body Measurements in Complete-Arch Digital Implant Impressions: An In Vitro StudyProsthesis · 2026
- Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study.Dentistry journal · 2026
- Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans.The Journal of prosthetic dentistry · 2026
- Digitization of a Single Tissue-Level Implant Without Scan Body - A Feasibility Study.Journal of dentistry · 2026
- Clinical Surface Alteration of Reciprocating Nickel-Titanium Instruments Following Root Canal Preparation and Sterilization: A Three-Dimensional FE-SEM-Based Analysis.International journal of dentistry · 2026