Effect of Scan Body Splinting on Geometric Scan-Body Measurements in Complete-Arch Digital Implant Impressions: An In Vitro Study
Georgia Vasileiadi, Katia Sarafidou, Evangelos Ximinis, Theodora Slini, Fotis Gogomitros, Konstantinos Krommydas, Olga Naka, Alexandros Tsouknidas,
Key points
From the paper's conclusion- Background/Objectives: This in vitro study evaluated the effect of PEEK scan body splinting on geometric scan-body measurements obtained from complete-arch digital implant scans using two intraoral scanners under two simulated clinical scenarios.
Abstract
Background/Objectives: This in vitro study evaluated the effect of PEEK scan body splinting on geometric scan-body measurements obtained from complete-arch digital implant scans using two intraoral scanners under two simulated clinical scenarios. Methods: Two 3D-printed edentulous maxillary models, each containing six implants at positions #16, #14, #12, #22, #24, and #26 (FDI notation), were evaluated. Model 1 contained parallel implants, whereas Model 2 included selected implants angulated 20° buccally or distally. Each model was scanned with the CS 3600 and TRIOS 3 under non-splinted (NSS) and PEEK-splinted (SS) conditions. Ten repeated scans were acquired per experimental condition (80 scans in total). After alignment to a common reference coordinate system, the scan-body longitudinal-axis vector magnitude (Vector, mm) and a composite angular metric (Δφ, °) were calculated at each implant position. Position-specific differences among NSS, SS, controlNSS, and controlSS groups were evaluated with Kruskal–Wallis tests followed, when appropriate, by Bonferroni-adjusted pairwise comparisons (α = 0.05). Results: Statistically significant NSS–SS differences were observed only at selected implant positions. For the CS 3600, significant differences involved Vector and/or Δφ, whereas for the TRIOS 3 they were confined to Δφ. In every statistically significant NSS–SS comparison, the SS group showed a lower mean value of the corresponding metric. More statistically significant NSS–SS differences were observed in Model 2 for the CS 3600 and in Model 1 for the TRIOS 3. These findings describe differences in the analyzed geometric metrics and should not be interpreted as direct test–reference trueness estimates. Conclusions: PEEK scan body splinting was associated with changes in scan-body geometric measurements at selected implant positions, but the effect was not uniform across scanners or experimental conditions. Because Vector and Δφ were not calculated as direct test–reference deviations, the present data do not establish improved trueness, precision, or overall scanning accuracy. Further studies using direct reference-based error metrics are required to determine clinical relevance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of different splinting configurations on the accuracy of complete-arch digital implant impressions: An in vitro study.Journal of clinical and experimental dentistry · 2026
- Trueness and Precision of Three Novel Scan Body Designs with Horizontal Extensions for Complete-Arch Implant Impressions: A Comparative In Vitro Study with Intraoral Scanning and Photogrammetry Systems.Journal of functional biomaterials · 2026
- Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring-Based Calibrated Framework: An In Vivo Study.Clinical oral implants research · 2026
- Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study.Dentistry journal · 2026
- Effect of Non-Splinting Techniques and Non-Calibrated Implant Scan Body Systems on the Accuracy of Complete-Arch Implant Scans: A Comparative Clinical Study.Clinical oral implants research · 2026
- Influence of splinted vs. non-splinted scan bodies on digital impression accuracy in all-on-four implant rehabilitation: a comparison with conventional open-tray impressions.BMC oral health · 2026