Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study.
Igor Blivajs, Igor Smojver, Yuval Reiser, Stella Jurić, Ena Hadžović, Ivica Pelivan, Dragana Gabrić
Department of Otolaryngology, Head and Neck Surgery, University Hospital Centre Zagreb, Kišpatićeva 12, HR-10000 Zagreb, Croatia. · Department of Oral Surgery, School of Dental Medicine, University of Zagreb, HR-10000 Zagreb, Croatia.
Key points
From the paper's conclusion- The findings do not demonstrate equivalence or clinically acceptable fit.
Abstract
Background: Scan body systems may affect the transfer of implant positions in complete-arch digital impressions. This in vitro study compared linear and angular deviations among three systems in a mandibular All-on-4 model. Methods: Ten repeated scans per system (exploratory sample) were acquired with a TRIOS 5 intraoral scanner for Straumann Titanium, Straumann Exact and TruAbutment ioConnect scan bodies. A laboratory-scanned cast from a conventional impression served as the reference; deviations are relative to this workflow. After conversion to a common geometry and complete-arch registration, linear deviations were measured in a standardized 2D cross-section and angular deviations between corresponding component axes. Scan-level means of four sites were compared using Welch's ANOVA and Games-Howell tests (α = 0.05). Results: Mean linear deviations were 0.187 ± 0.025 mm (Exact), 0.234 ± 0.005 mm (Titanium) and 0.135 ± 0.060 mm (TruAbutment; p < 0.001). Titanium exceeded Exact (p < 0.001) and TruAbutment (p = 0.0014); Exact and TruAbutment did not differ significantly (p = 0.060). Mean angular deviations were 1.304 ± 0.067°, 2.691 ± 0.139° and 1.380 ± 0.065° (p < 0.001); Titanium exceeded both systems (p < 0.001), but Exact-TruAbutment did not (p = 0.050). Conclusions: Within this model and reference workflow, Titanium showed greater linear and angular deviations than Exact and TruAbutment. No difference was established between Exact and TruAbutment. The findings do not demonstrate equivalence or clinically acceptable fit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trueness and Precision of Three Novel Scan Body Designs with Horizontal Extensions for Complete-Arch Implant Impressions: A Comparative In Vitro Study with Intraoral Scanning and Photogrammetry Systems.Journal of functional biomaterials · 2026
- Effect of Scan Body Geometry and CAD Software on the Accuracy of Implant-Position Transfer: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2026
- Accuracy of 12 Intraoral Scanners and Photogrammetric Systems for Full-Arch Edentulous Maxillae: An In Vitro Study.The International journal of periodontics & restorative dentistry · 2026
- From Digital Deviation to Clinical Fit: Do Inter-Scanner Discrepancies Predict Passive-Fit Differences in Full-Arch Implant Rehabilitation?Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995) · 2026
- A centripetally rotating implant scan body concept for complete-arch scanning: An in vitro studyJournal of Dentistry · 2026
- Accuracy of full-arch implant scan with Nexus IOS® scan gauges versus different conventional scan bodies: An in vitro comparative studyJournal of Dentistry · 2025