Pulse Oximetry Versus Arterial Co-Oximetry During Exercise: A Systematic Review of Agreement and Sensor Technology Reporting Gaps.
Shu Xie, Xueming Wen
School of Exercise and Health, Shanghai University of Sport, 650 Qingyuanhuan Road, Yangpu District, Shanghai 200438, China.
Key points
From the paper's conclusion- These data do not establish a universal correction factor or a transportable substitution rule.
Abstract
Pulse oximetry is an optical biosensor for peripheral oxygen-saturation monitoring, but its agreement with arterial co-oximetry during exercise remains uncertain. We searched three databases through 30 August 2026 and conducted supplementary Embase searching in September. Sixteen studies yielded 46 device- or condition-level outcomes. Across four peak/maximal cohorts, mean bias ranged from -0.88 to +2.63 percentage points. Three reported paired SDs ranged from 2.75 to 4.60 points; a fourth was conditionally reconstructed. Primary synthesis was structured and descriptive. Post hoc random-effects mean-bias analyses of three reported-SD cohorts and a conditional fourth were imprecise and clinically heterogeneous, and did not characterize individual agreement. A descriptive technology audit found complete device identification in 14 studies and sensor-site reporting in 15, but no study fully reported numerical emitter wavelengths. Averaging/update behavior was fully reported in two studies, algorithm/post-processing detail in three, motion handling in six, and failure/missingness in seven. The author-agreed appraisal was interpreted descriptively without validated aggregate risk or certainty grades. These data do not establish a universal correction factor or a transportable substitution rule. No prospective registration, incomplete supplementary-search export reconciliation and reference-construct ambiguity limit interpretation. More complete sensor, reference-method and agreement reporting is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance validation of a new finger-root-adapted ring-shaped oximeter sensor during stepwise steady-state inspired hypoxia.Journal of clinical monitoring and computing · 2026
- Evaluating Continuous SpO2 as a Lactate-Threshold Marker: Implications for Wearable Sports-Monitoring SystemsSignals · 2026
- Accuracy and Reliability of Pulse Oxygen Saturation Measured Using Wrist-Worn Oximeters.International journal of sports medicine · 2026
- P017. Agreement between two commonly used pulse oximeters during in-laboratory polysomnographySLEEP advances · 2026
- Agreement of consumer wearable pulse oximeters across activity conditions and skin pigmentation.Frontiers in digital health · 2026
- Pulse Oximeter Performance and Skin Pigment: Comparison of 34 Oximeters Using Current and Emerging Regulatory FrameworksAnesthesia & Analgesia · 2026