Effect of Scan Body Geometry and CAD Software on the Accuracy of Implant-Position Transfer: An In Vitro Study.
Max-Michael Blechschmidt, Ragai Edward Matta, Fynn-Ole Petersen, Manfred Wichmann, Felix Förtsch
Department of Prosthodontics, Erlangen University Hospital, Friedrich-Alexander-University Erlangen-Nuremberg, Glueckstrasse 11, 91054 Erlangen, Germany.
Key points
From the paper's conclusion- These findings suggest that scan body system and CAD software should be considered jointly when evaluating implant-position transfer accuracy.
Abstract
Accurate transfer of implant position to the virtual model is essential for digital implant prosthodontic workflows. Although scan body geometry and CAD software may affect this process, evidence regarding their combined effect remains limited. This in vitro study evaluated the effects of two scan body systems and three CAD software programs on implant-position transfer accuracy and assessed their interaction. An edentulous maxillary titanium model with three implants was digitized ten times for each of two scan body systems. Each data set was processed with exocad, 3shape, and DWOS. Implant-position transfer was assessed as the three-dimensional Euclidean deviation of standardized scan body reference points. Data were analyzed using a two-way mixed repeated-measures ANOVA and Holm-adjusted pairwise comparisons (α = 0.05). Scan body system, CAD software, and their interaction significantly affected transfer accuracy (p < 0.001). Medentika showed lower mean deviations than NT-Trading with all software programs, although the difference was not significant with 3shape. For NT-Trading, 3shape produced significantly lower deviations than exocad and DWOS, whereas for Medentika, exocad produced significantly lower deviations than DWOS, with no significant differences between 3shape and either exocad or DWOS. Implant-position transfer accuracy depended on the specific combination of scan body system and CAD software. These findings suggest that scan body system and CAD software should be considered jointly when evaluating implant-position transfer accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study.Dentistry journal · 2026
- Trueness and Precision of Three Novel Scan Body Designs with Horizontal Extensions for Complete-Arch Implant Impressions: A Comparative In Vitro Study with Intraoral Scanning and Photogrammetry Systems.Journal of functional biomaterials · 2026
- Extraoral relocation of implant scanbody geometries: An in vitro comparison of two workflows for complete-arch implant position transfer.Journal of dentistry · 2026
- Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body-independent technique.The Journal of prosthetic dentistry · 2026
- Accuracy of 12 Intraoral Scanners and Photogrammetric Systems for Full-Arch Edentulous Maxillae: An In Vitro Study.The International journal of periodontics & restorative dentistry · 2026
- Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported RestorationsDentistry Journal · 2026