Trueness and Precision of Three Novel Scan Body Designs with Horizontal Extensions for Complete-Arch Implant Impressions: A Comparative In Vitro Study with Intraoral Scanning and Photogrammetry Systems.
Üzeyir Arslan, Gülümser Evlioğlu, Erkan Sancaklı, Emrah Baca
Department of Prosthodontics, Faculty of Dentistry, Istanbul University, 34116 Istanbul, Türkiye.
Key points
From the paper's conclusion- This in vitro study evaluated the trueness and precision of three novel auxiliary scan body designs with two horizontal extensions, additively manufactured by vat photopolymerisation, primarily against original manufacturer scan bodies and secondarily against a partial dentition scanning protocol and three photogrammetry systems (two extraoral, one intraoral).
Abstract
Accurate transfer of implant positions is critical for complete-arch implant-supported rehabilitations, yet intraoral scanning accuracy degrades over long edentulous spans, where errors accumulate. This in vitro study evaluated the trueness and precision of three novel auxiliary scan body designs with two horizontal extensions, additively manufactured by vat photopolymerisation, primarily against original manufacturer scan bodies and secondarily against a partial dentition scanning protocol and three photogrammetry systems (two extraoral, one intraoral). Four implants (Ø 3.8 × 10 mm) were placed in a prefabricated polyurethane edentulous maxillary model; anterior implants were parallel and perpendicular to the occlusal plane, while posterior implants were angled at 30°. Nine groups were assessed: one reference dataset and eight study groups, the latter each comprising 12 repeated scans. Deviations were calculated as differences in inter-implant centre distances (linear, µm) and inter-axis angles (angular, degrees) relative to a laboratory optical scanner. Group differences were significant for all endpoints (p < 0.001). Mean linear deviations ranged from 31 ± 4 µm to 58 ± 18 µm and mean angular deviations from 0.068 ± 0.012° to 0.538 ± 0.250°. No group exceeded the 100 µm mean linear threshold; one photogrammetry system exceeded the 0.40° mean angular threshold. Linear and angular results followed different rankings and should be evaluated separately.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of 12 Intraoral Scanners and Photogrammetric Systems for Full-Arch Edentulous Maxillae: An In Vitro Study.The International journal of periodontics & restorative dentistry · 2026
- Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study.Dentistry journal · 2026
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of complete-arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of complete-arch implant impressions obtained with intraoral scanning, calibrated intraoral scan protocol, extraoral and intraoral photogrammetry, and conventional impression techniques: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro studyJournal of Dentistry · 2025