Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations
Cristian Abad‐Coronel, David Ruiz, Miguel Ángel Quelal, Diana Margarita Díaz Estrada, Nancy Mena Córdova, Paulina Aliaga
University of Cuenca · Universidad San Francisco de Quito
Key points
From the paper's conclusion- Conclusions: Under controlled in vitro conditions, both digital impression techniques and conventional splinted protocols achieve high three-dimensional accuracy and clinically acceptable passive fit for multi-implant-supported fixed prostheses.
Abstract
Background: Digital technologies, particularly CAD/CAM workflows, have transformed implant prosthodontics by improving the accuracy and efficiency of impression procedures, facilitating clinician–laboratory communication, and supporting the preservation of peri-implant tissues. Objective: To compare the three-dimensional accuracy (trueness) and passive fit of five conventional and digital impression techniques for fixed prostheses supported by two implants. Methods: An in vitro experimental study was conducted using a partially edentulous maxillary model with two implants supporting a three-unit zirconia bridge. Five impression workflows were evaluated: conventional techniques (open-tray and closed-tray, splinted and non-splinted) and digital impressions using plastic and titanium scan bodies. Three-dimensional accuracy was assessed by digital superimposition analysis, and passive fit was evaluated by marginal gap measurements using digital microscopy and ImageJ (version 1.54r) software. Statistical analyses were performed using exploratory ANOVA with Welch’s correction and Games–Howell post hoc tests (p < 0.05), complemented by effect size analysis. Results: Three-dimensional superimposition analysis revealed that digital impression workflows and the splinted conventional open-tray technique exhibited the highest trueness, with minimal spatial deviations relative to the reference model, together with the lowest marginal gap values (<1 µm). The non-splinted open-tray technique presented higher discrepancies (7.37 ± 0.94 µm), although all techniques remained within clinically acceptable tolerance ranges (60–150 µm). Conclusions: Under controlled in vitro conditions, both digital impression techniques and conventional splinted protocols achieve high three-dimensional accuracy and clinically acceptable passive fit for multi-implant-supported fixed prostheses. Digital workflows represent a predictable and efficient alternative, while conventional splinted impressions remain a reliable option depending on clinical and technological considerations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Marginal and internal fit accuracy of single-crown restorations: the impact of digital and conventional impression techniquesBMC Oral Health · 2025
- Influence of Digital Versus Analogue Workflows on the Clinical Marginal and Internal Fit of CAD/CAM Zirconia Fixed Restorations: A Systematic Review and Meta-AnalysisProsthesis · 2026
- In Vivo Complete Arch Implant Impressions: Comparison of the Linear Precision of Digital and Conventional TechniquesInternational Dental Journal · 2026
- The Accuracy of Digital vs Conventional Impression among Patients Receiving Dental Implants: A Systematic Review and Meta Analysis of Clinical Studies : Short title: Digital vs Conventional Impression among Patients Receiving Dental Implants.Galen medical journal · 2026
- From Digital Deviation to Clinical Fit: Do Inter-Scanner Discrepancies Predict Passive-Fit Differences in Full-Arch Implant Rehabilitation?Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995) · 2026
- Digital era in oral rehabilitation: a scoping review of trends and implications for clinical practice.Brazilian oral research · 2026