Effect of Tightening Protocol on Reverse Torque and Plastic Deformation of Dynamic and Conventional Titanium Abutment Screws.
Ricardo Batista, André Moreira, Rui B Ruben, Maria Helena Figueiral, Nuno Alves, João Carlos Sampaio-Fernandes
Faculty of Dental Medicine, University of Porto, Rua Dr. Manuel Pereira da Silva, 4200-393 Porto, Portugal. · CDRSP, University of Leiria and Oeste, 2430-028 Leiria, Portugal.
Key points
From the paper's conclusion- Preload loss is intrinsic to abutment screw tightening irrespective of design; RTV behaviour under repeated cycling is system-dependent, and abutment screws should be treated as limited-use components.
Abstract
Preload loss and plastic deformation of titanium abutment screws under repeated tightening are clinically significant yet incompletely characterized across systems with differing head geometries and surface treatments. Two ISO 14801-certified titanium screws were evaluated: hexalobular-head gold-plated (Gold-Tite®; 3i Zimmer Biomet, now ZIMVIE) and anodized star-shaped (Vega®; Klockner®). Six groups (n = 5 screws) varied by screw type, torque (20-40 N·cm), and cycle count (10 or 20). Reverse torque value (RTV) was recorded at every cycle and analyzed at the screw level; a linear mixed-effects model (screw as random effect) characterized how RTV evolved across cycles, with screw-level non-parametric tests for between-protocol contrasts. Micro-CT (19.9 μm; n = 3 per group) used Otsu segmentation. RTV was lower than insertion torque in every screw (30/30; 73-89% of applied torque). RTV declined significantly across cycles in the Vega/Klockner system (-0.17 N·cm per cycle, p = 0.006) but not in the ZFX/ZIMVIE system (p = 0.302), which showed greater between screw variability. Between protocol contrasts at n = 5 were null or underpowered. Micro-CT showed head localized change in both systems (mean cross-sectional area essentially unchanged); in the ZFX/ZIMVIE screws, this change appeared specifically under the over-use condition, whereas the Klockner screws showed comparable head change across all protocols. Preload loss is intrinsic to abutment screw tightening irrespective of design; RTV behaviour under repeated cycling is system-dependent, and abutment screws should be treated as limited-use components.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of different abutment materials on torque maintenance and screw loosening in implant-supported prostheses.Bioinformation · 2026
- Influence of Different Surface Modifications on the Reverse Torque Values of Abutment Screws: An In Vitro Study.Journal of functional biomaterials · 2026
- The impact of abutment manufacturing techniques on reverse torque after cyclic loading and implant-abutment interface fitting: an in vitro study.BMC oral health · 2026
- Effect of cyclic loading on screw loosening in fixed partial dentures supported by the OT bridge versus multi-unit angled abutments: An in vitro study.The Journal of prosthetic dentistry · 2026
- A comparative analysis of efficacy of torque limiting devices provided by different dental implant manufacturersBMC Oral Health · 2026
- A Novel Abutment Screw Head Design with an Integrated Retrieval Feature: An In Vitro Study.Dentistry journal · 2026