Influence of Different Surface Modifications on the Reverse Torque Values of Abutment Screws: An In Vitro Study.
Merve Dede, Ozgun Yusuf Ozyilmaz, Ozge Doganay Ozyilmaz, Gamze Hanci Abay
Department of Prosthodontics, Faculty of Dentistry, Istanbul Galata University, 34430 Istanbul, Turkey. · Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Bezmialem Vakif University, 34093 Istanbul, Turkey.
Key points
From the paper's conclusion- This study evaluated the reverse torque values (RTVs) of abutment screws with different surface modifications.
Abstract
Evidence regarding tantalum nitride (TaN)-coated gold abutment screws is lacking, and studies on diamond-like carbon (DLC)-coated and anaerobic adhesive-coated abutment screws remain limited. This study evaluated the reverse torque values (RTVs) of abutment screws with different surface modifications. Sixty abutment screws from the same implant system were divided into five groups (n = 12): gold, TaN-coated gold, titanium, DLC-coated titanium, and anaerobic adhesive-coated titanium. Abutments were tightened according to the manufacturer's recommended torque. Specimens were then subjected to cyclic loading (50 N, 1 Hz, 480,000 cycles) in a dual-axis chewing simulator, after which RTVs were evaluated. ANOVA showed a significant difference only for the uncoated gold screw group (p < 0.05). The lowest RTVs were observed in the gold screws. Although the differences among the modified screw groups were not statistically significant, surface-treated screws demonstrated higher and more stable RTVs than their uncoated counterparts. TaN-, DLC-, and anaerobic adhesive-treated screws exhibited higher RTVs following cyclic loading, suggesting that these surface modifications may enhance screw stability and reduce the risk of abutment screw loosening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Tightening Protocol on Reverse Torque and Plastic Deformation of Dynamic and Conventional Titanium Abutment Screws.Bioengineering (Basel, Switzerland) · 2026
- Influence of different abutment materials on torque maintenance and screw loosening in implant-supported prostheses.Bioinformation · 2026
- Influence of Antimicrobial Sealing Gels on Reverse Torque Values of Implant-Abutment Screws Following Thermomechanical Loading: A Comparative In Vitro Study.Polymers · 2026
- A Novel Abutment Screw Head Design with an Integrated Retrieval Feature: An In Vitro Study.Dentistry journal · 2026
- The impact of abutment manufacturing techniques on reverse torque after cyclic loading and implant-abutment interface fitting: an in vitro study.BMC oral health · 2026
- Influence of Prosthetic Screw Designs with and Without Titanium Base on the Fracture Resistance of Implant-Supported Zirconia Frameworks.Materials (Basel, Switzerland) · 2026