Applied Sciences

Review of Neutral Grounding Modes, Resistor Monitoring, and Methodology for Transitioning to Resistive Grounding in 6–10 kV Distribution Networks

Iliya Iliev, Alexandr Nazarychev, Andrey Grigorov, Ivan Beloev, Konstantin Suslov, Hristo Beloev

Review

Key points

From the paper's conclusion
  • A significant part of the review is devoted to substantiating the phased conversion of 6–10 kV distribution networks with isolated or compensated neutral to resistive grounding.

Abstract

With increasingly stringent requirements for the reliability and safety of medium-voltage distribution networks, the problem of selecting and monitoring the neutral grounding mode is becoming increasingly important. This review focuses on a comprehensive analysis of neutral grounding modes in medium-voltage distribution networks and on methods for detecting single-phase ground faults, which account for up to 80% of all faults. The review provides a comparative analysis of the main neutral grounding modes, namely isolated, compensated, resistive, and combined neutral. Their advantages and disadvantages are identified in terms of overvoltage levels, personnel safety, relay protection selectivity, and other factors. Modern and conventional methods for detecting single-phase ground faults are also considered. Particular attention is paid to the problem of monitoring the technical condition of neutral grounding resistors, since their latent failure can lead to unpredictable consequences. An analysis of existing monitoring methods is carried out, and the need for a combined method for continuous monitoring is substantiated. A significant part of the review is devoted to substantiating the phased conversion of 6–10 kV distribution networks with isolated or compensated neutral to resistive grounding. It also presents a methodological approach for determining the priority order of substation modernization based on calculating an integrated priority indicator using the analytic hierarchy process (AHP) and the pairwise comparison method. This approach allows heterogeneous technical and organizational factors to be taken into account and enables objective ranking of substations for conversion to resistive grounding.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Review of Neutral Grounding Modes, Resistor Monitoring, and Methodology for Transitioning to Resistive Grounding in 6–10 kV Distribution Networks — Science Skim