Multipath Architecture for Ground Fault Detection in DC-Links of High-Voltage AC Drives Using Neutral-Point Voltage
Jooyeon Lee, Kitak Ryu, Hongyu Zhao, Jongkap Ahn, Yude Shao, Yunhyung Lee
Key points
From the paper's conclusion- The results establish a direct link between the conductance model, nonlinear sensitivity characteristics, and multipath ground fault detection.
Abstract
Ground fault detection in DC-links of high-voltage AC drives is challenging because faults may not produce large currents, while neutral-point voltage monitoring can lose sensitivity under nearly balanced pole-to-ground conductances. This paper develops a physics-based mathematical model and a multipath detection framework for the 5 kV DC-link of the GE MV7306 drive. A closed-form expression for the neutral-point voltage VDC0 is derived using Kirchhoff’s current law in terms of equivalent pole-to-ground conductances. A normalized conductance asymmetry index characterizes near-balanced conditions, and logarithmic resistance sensitivity identifies the characteristic transition, Gfault=Gref, beyond which the neutral-point voltage approaches saturation. The analytical model is also used to relate the fixed voltage threshold to the corresponding fault conductance and fault resistance boundaries. A multipath architecture combining fixed-threshold and robust adaptive-threshold paths is then developed. Circuit-model-based simulations consider degradation–recovery, variable-resistance surface leakage, and near-symmetric conductance oscillation scenarios. The proposed method detects all three scenarios with delays of 1.213, 0.031, and 0.141 s, respectively. For the two scenarios detected by both the proposed method and the fixed-threshold baseline, the mean detection delay decreased from 0.822 to 0.622 s, a 24.3% reduction. The results establish a direct link between the conductance model, nonlinear sensitivity characteristics, and multipath ground fault detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design of a comprehensive protection algorithm for fault detection, classification, and location in high voltage direct current transmission lines connected to wind farms based on local terminal measurements.PloS one · 2026
- Review of Neutral Grounding Modes, Resistor Monitoring, and Methodology for Transitioning to Resistive Grounding in 6–10 kV Distribution NetworksApplied Sciences · 2026
- Fault-Section Location System and Strategy for Single-Phase Ground Faults in Flexible-Grounded Distribution NetworksElectronics · 2026
- Physically Interpretable Series Arc Fault Detection via Hilbert Transform-Derived Half-Cycle Energy Ratios and LightGBMEnergies · 2026
- Rapid identification method of commutation failure risk areas in HC-HVDC systems under single-phase faultsInternational Journal of Electrical Power & Energy Systems · 2025
- Improving the Measurement Accuracy of HVDC Grounding Impedance Under Multilayer Soil Uncertainty for Energy Engineering ApplicationsAlgorithms · 2026