From the paper's conclusion- Multivariate regression demonstrated that the first operator’s radiation dose rate was associated with patient body mass index (BMI) ≥ 25 kg/m 2 ( p = 0.030), the operator’s experience ( p = 0.026), the operator’s height ( p = 0.011), the visual field size ( p = 0.007), and the type of interventional transarterial embolization procedure ( p < 0.050).
Abstract
Objective This study aimed to record operators’ radiation doses during routine transarterial embolization using a real-time radiation dosimeter and to investigate the influencing factors of occupational radiation exposure. Materials and methods A total of 222 transarterial embolization procedures, including 133 transarterial chemoembolization (TACE), 35 bronchial artery embolization (BAE), 26 renal artery embolization (RAE), 15 uterine artery embolization (UAE), and 13 genicular artery embolization (GAE) procedures, were prospectively enrolled. Data related to patient characteristics, operator information, and radiation dose parameters were recorded. The kerma-area product ( P KA ) and effective dose (ED) were used to quantify patients’ radiation dose. The operator radiation dose equivalent, Hp(10), was recorded using a real-time dosimeter placed outside the lead apron at the left upper chest. The Mann–Whitney U test, the Kruskal–Wallis H test, and multivariate linear regression analysis were performed. Results In this investigation, 19 patients (9.79%) had an ED greater than 100 mSv. The GAE procedures were associated with significantly prolonged fluoroscopy time and higher radiation doses for first operators, whereas the UAE group yielded higher fluoroscopy P KA and air kerma ( K a,r). Both fluoroscopy time and the fluoroscopy P KA were correlated with the first operators’ radiation doses. The first operators received higher radiation doses than secondary operators during TACE, BAE, RAE, UAE, and GAE procedures. Multivariate regression demonstrated that the first operator’s radiation dose rate was associated with patient body mass index (BMI) ≥ 25 kg/m 2 ( p = 0.030), the operator’s experience ( p = 0.026), the operator’s height ( p = 0.011), the visual field size ( p = 0.007), and the type of interventional transarterial embolization procedure ( p < 0.050). Conclusion Operators’ radiation doses varied across different transarterial embolization procedures. Fluoroscopy time and P KA , the operator’s position, height, and experience, and the visual field size were related to the operators’ radiation dose.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time Radiation Exposure Monitoring in the Cardiac Catheterization Laboratory Using a Digital RRPD Dosimeter.Health physics · 2026
- Patient Radiation Dose Indices and Preliminary Local Diagnostic Reference Levels in Preoperative Intracranial Tumour Embolization Using a Low-Dose Protocol: A Single-Centre StudyBiomedicines · 2026
- Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study.Frontiers in public health · 2026
- Effective Dose Evaluation of Cerebral Angiography Using Kerma Area Product and Development of Effective Dose Conversion Factors.Diagnostics (Basel, Switzerland) · 2026
- Quantifying per-event dose-equivalent rates of echocardiographers and interventional cardiologists during structural heart interventions.Radiological physics and technology · 2026
- Operator Radiation Dose in C-Arm Fluoroscopy: A Narrative Review of Region- and Procedure-Specific Evidence and a Practical Framework for Intraoperative Dose EstimationSurgeries · 2026