Radiological physics and technology

Quantifying per-event dose-equivalent rates of echocardiographers and interventional cardiologists during structural heart interventions.

Katsunori Yamashita, Kosuke Matsubara

Department of Radiology, Hamamatsu University Hospital, Hamamatsu, Shizuoka, Japan. · Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan. k.matsubara@staff.kanazawa-u.ac.jp.

Observational

Key points

From the paper's conclusion
  • We quantified the per-event personal dose equivalent rate at a 10-mm depth [Hp(10)] for ECs and ICs during SHIs and identified its determinants.

Abstract

Echocardiographers (ECs) often stand close to the patient during structural heart interventions (SHIs) and may receive higher occupational radiation exposure than interventional cardiologists (ICs). Previous studies have relied on cumulative dose measurements, leaving the per-event determinants of occupational radiation dose poorly characterized. We quantified the per-event personal dose equivalent rate at a 10-mm depth [Hp(10)] for ECs and ICs during SHIs and identified its determinants. We prospectively analyzed 37 SHI cases (20 mitral transcatheter edge-to-edge repair procedures and 17 left atrial appendage occlusion procedures) at a single center between March 2024 and March 2025. The EC and IC each wore two semiconductor dosimeters (on the front and side of the neck) sampling at 1 Hz, and the higher reading was used for analysis. Per-event Hp(10) rates were calculated by integrating dosimetry data, radiation dose structured report information, and video-based shielding labels. A prespecified linear mixed-effects model with a case-level random intercept assessed X-ray output, beam geometry, operator shielding, and C-arm angulation as candidate determinants for each operator. Among 3,222 exposure events, the EC-to-IC ratio of the Hp(10) rate was 2.3 during fluoroscopy and 3.8 during cine acquisition (both p < 0.001). In the multivariable model, log10(Ka,r rate), protocol, C-arm angle, source-to-detector distance, field of view, and operator shielding were independent predictors of the Hp(10) rate for both operators. The EC experienced substantially higher per-event Hp(10) rates than the IC, particularly during cine acquisition. Operator-specific shielding strategies and per-event optimization of X-ray output are warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Quantifying per-event dose-equivalent rates of echocardiographers and interventional cardiologists during structural heart interventions — Science Skim