Effective Dose Evaluation of Cerebral Angiography Using Kerma Area Product and Development of Effective Dose Conversion Factors.
Jeongbok Min, Jungsu Kim
Department of Bio-Health Convergence Major in Medical Convergence Radiologic-Technology, Graduate School of Health Technology, Daegu Health College, Daegu 41453, Republic of Korea. · Department of Radiological-Technology, Daegu Health College, Daegu 41453, Republic of Korea.
Key points
From the paper's conclusion- The findings demonstrated substantial radiation absorption in the head and neck regions, providing critical data for routine dose monitoring.
Abstract
Background/Objectives: Transfemoral cerebral angiography (TFCA) involves significant radiation exposure because of prolonged fluoroscopy and repeated imaging sequences. Because complex dose simulations are often infeasible in routine clinical practice, this study employed PC-based Monte Carlo methods to estimate organ-absorbed and effective doses. The primary objective was to establish Kerma area product (KAP)-based conversion factors to facilitate efficient clinical dose assessment. Methods: We analyzed 30 patients who underwent TFCA. Key parameters, including total KAP, tube voltage, and projection angles, were obtained from DICOM Radiation Dose Structured Reports. Monte Carlo simulations were conducted for anteroposterior, lateral, and cranial planes. The conversion factors were then derived by calculating the ratio of the effective dose to the total KAP. Results: The average KAP was 36.23 ± 6.81 Gy·cm2. Effective doses calculated via Monte Carlo simulation were 1.70 ± 0.35 mSv under International Commission on Radiological Protection (ICRP) 60 and 1.90 ± 0.40 mSv under ICRP 103 standards. The corresponding conversion factors were 0.0468 ± 0.0054 and 0.0525 ± 0.0065 mSv/Gy·cm2 respectively. Notably, the ICRP 103-based factor was 12.2 percent higher than the ICRP 60-based factor, reflecting updated tissue weighting factors in modern dosimetry. Conclusions: This study provides standardized conversion factors that allow rapid and reliable dose estimation without requiring complex simulations. The findings demonstrated substantial radiation absorption in the head and neck regions, providing critical data for routine dose monitoring. These results emphasize the importance of rigorous radiation protection and safety protocols during interventional procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Operator Radiation Dose in C-Arm Fluoroscopy: A Narrative Review of Region- and Procedure-Specific Evidence and a Practical Framework for Intraoperative Dose EstimationSurgeries · 2026
- Patient radiation dose in diagnostic cerebral angiography for intracranial aneurysm: local diagnostic reference levels from a single-center study in Thailand.Radiation protection dosimetry · 2026
- Identifying High-Dose Views and Modes in the Catheterization Laboratory: A Run-Level Mixed-Effects Analysis.Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2026
- Angio-CT does not increase patient radiation exposure compared to conventional cone-beam CT for intra-arterial liver procedures.European radiology · 2026
- Real-time dosimetry in interventional radiology—comparing the operators’ radiation dose and associated factors for five types of transarterial embolization proceduresFrontiers in Public Health · 2026
- CT image-based evaluation of phantom-derived DLP-to-effective dose conversion factors for adult abdomen-pelvis CT.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026