Respiratory function monitoring during neonatal resuscitation: a crossover study of high-fidelity simulated bronchopulmonary dysplasia.
Allan Jenkinson, Kerstin Jost, Janneke Dekker, Emma Williams, Almudena Alonso-Ojembarrena, Anna Lavizzari, Benjamin Stoecklin, Olivier Danhaive,
Department of Women and Children's Health, King's College London, London, United Kingdom. · Department of Women's and Children's Health, Karolinska Institute, Stockholm, Sweden.
Key points
From the paper's conclusion- Conclusion During simulated resuscitation of bronchopulmonary dysplasia, participants were more likely to achieve a tidal volume within the intended range and a higher respiratory rate when they had real-time RFM feedback compared to when such feedback was not available.
Abstract
PURPOSE: We aimed to test the hypothesis that respiratory function monitoring (RFM) during neonatal resuscitation can reduce mask leak and the delivery of inadvertently high tidal volumes. METHODS: We used a high fidelity neonatal manikin mimicking the lung mechanics of bronchopulmonary dysplasia. Neonatal clinicians provided positive pressure ventilation with a bag-valve and mask while blinded and while unblinded to the RFM, displaying the leak and the tidal volume. RESULTS: The median (IQR) inspiratory tidal volume when blinded to the RFM [8.3 (7.1-10.6) ml/kg] was significantly higher compared to when unblinded to the RFM [6.7 (5.8-8.3) ml/kg, p = 0.002]. The expiratory tidal volume when blinded to the RFM [6.5 (5.8-7.8) ml/kg] was significantly higher compared to when unblinded to the RFM [5.7 (5.1-6.9) ml/kg, p = 0.021]. The percentage of leak was not different when blinded to the RFM compared to when unblinded. The peak inflation pressure was not different when blinded to the RFM compared to when unblinded. CONCLUSION: During simulated resuscitation of bronchopulmonary dysplasia, participants were more likely to achieve a tidal volume within the intended range and a higher respiratory rate when they had real-time RFM feedback compared to when such feedback was not available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of real-time respiratory function monitoring on neonatal mask ventilation training: a multicentre simulation-based crossover study.BMJ paediatrics open · 2026
- Discrepancy in applied tidal volumes between t-piece and lung level during delivery room stabilization - a case report.Frontiers in pediatrics · 2026
- Real-time feedback during bag-valve-mask ventilation for out-of-hospital cardiac arrest: a before-and-after study (VEntilation during Cardiac Arrest Resuscitation Study, VECARS-2).Resuscitation · 2026
- Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study.Pediatrics · 2026
- From assumption to assurance: Real-time flow monitoring in neonatal infusions.The journal of vascular access · 2026
- Accuracy of ventilation feedback devices compared with a reference standard during asynchronous ventilation with continuous chest compressions in a simulated cardiac arrest: a prospective non-randomized cross-over study.Resuscitation plus · 2026