Real-time feedback during bag-valve-mask ventilation for out-of-hospital cardiac arrest: a before-and-after study (VEntilation during Cardiac Arrest Resuscitation Study, VECARS-2).
Daniel Jost, Alexandre Petermann, Bruno Tassart, Marina Salome, Frédéric Lemoine, Justin Liscia, Benoît Frattini, Clément Derkenne,
Paris Fire Brigade Emergency Medicine Department, 1 place Jules Renard, 75017 Paris, France; Sudden Death Expertise Center, Université Paris Cité, INSERM U970 Paris Cardiovascular Research Centre, Paris, France. Electronic address: Daniel.jost@pompiersparis.fr. · Paris Fire Brigade Emergency Medicine Department, 1 place Jules Renard, 75017 Paris, France.
Key points
From the paper's conclusion- This study compared bag-valve-mask ventilation quality and adherence to the guideline-recommended ventilation volume range during 30:2 cardiopulmonary resuscitation for out-of-hospital cardiac arrest before and after the implementation of real-time feedback.
Abstract
This study compared bag-valve-mask ventilation quality and adherence to the guideline-recommended ventilation volume range during 30:2 cardiopulmonary resuscitation for out-of-hospital cardiac arrest before and after the implementation of real-time feedback. We conducted a before-and-after observational study of two sequential adult cohorts with out-of-hospital cardiac arrest managed by basic life support teams from the Paris Fire Brigade. A bidirectional sensor measured insufflated volume (Vi) and expiratory tidal volume (Vt). The display was masked during Period-1 and provided real-time feedback during Period-2. We assessed adherence to the guideline-recommended range using mixed-effects regression; we analyzed Vt and leak volume using gamma log-link generalized linear mixed models. We analyzed 4,300 ventilations in 163 patients, 96 without feedback and 67 with feedback. Median Vi was lower with feedback (471 mL) than without (513 mL, p=0.03 for the first ventilation of each cycle) but median Vt was unchanged (235 vs. 243 mL, p=0.84). Vi dispersion was reduced by 35% (mean within-patient IQR ratio 0.65 [95%-CI, 0.53-0.77]). Vi was 400-600 mL in 68% of ventilations with feedback vs. 42% without feedback. In contrast, Vt was 400-600 mL in only 14% of ventilations with feedback vs. 15% without feedback. In multivariable analysis, leak volume was 12% lower with feedback (mean ratio, 0.88 [95%-CI, 0.77-0.99]). Real-time feedback was associated with improved adherence to the guideline-recommended range for Vi, less dispersed Vi,and lower leak volume. Causal inference, clinical significance, and generalizability warrant further evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-world adoption and use of a ventilation feedback device during out-of-hospital cardiac arrest: a population-based observational study from a French prehospital system.Resuscitation plus · 2026
- Ventilation Monitoring in Out-of-Hospital Cardiac Arrest Care.Resuscitation · 2026
- Accuracy of ventilation feedback devices compared with a reference standard during asynchronous ventilation with continuous chest compressions in a simulated cardiac arrest: a prospective non-randomized cross-over study.Resuscitation plus · 2026
- Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study.Pediatrics · 2026
- Agreement and Reliability of a Newly Developed Tidal Volume Monitoring Device in Bag-Valve Ventilation and Intubation Scenarios: A Simulation-Based Study.Bioengineering (Basel, Switzerland) · 2026
- Influence of different airway devices on intra-arrest ventilation during bag-valve-device ventilation - a prospective randomized controlled cadaver studyCritical Care · 2025