Impact of real-time respiratory function monitoring on neonatal mask ventilation training: a multicentre simulation-based crossover study.
Latifah Alrashed, Eliane Bodanese
Department of Electronic Engineering and Computer Science, Queen Mary University of London, London, UK acw602@qmul.ac.uk lsalrashed@pnu.edu.sa. · School of Electronic Engineering and Computer Science, Queen Mary University of London, London, UK.
Key points
From the paper's conclusion- In this multicentre crossover simulation study, visible RFM feedback was associated with changes in mask ventilation performance and evidence of a carry-over learning effect following feedback removal. Real-time visibility of respiratory parameters may strengthen neonatal resuscitation training.
Abstract
OBJECTIVE: To evaluate whether visibility of respiratory function monitor (RFM) feedback improves mask ventilation performance and influences subsequent ventilation performance during neonatal resuscitation training. DESIGN: multicentre randomised crossover simulation study. PARTICIPANTS: Healthcare professionals involved in neonatal resuscitation training across participating centres. INTERVENTION: Participants performed positive pressure ventilation (PPV) on both term and premature manikins under two conditions: with visible RFM feedback and with the display masked. The order of feedback visibility was randomised. Each participant completed ventilation assessments in both conditions. MAIN OUTCOME MEASURES: Primary outcomes were expired tidal volume (Vte) and mask leak (%). The proportion of breaths within the target Vte range (4-8 mL/kg) was calculated as a performance indicator. Secondary outcomes included variability in Vte and mask leak to assess ventilation stability between conditions. RESULTS: Visible RFM feedback was associated with lower mask leak and improved ventilation stability in the preterm manikin and with tidal volumes entering the target range in the term manikin. Participants initially ventilated with visible feedback maintained performance after feedback removal, suggesting a carry-over learning effect. CONCLUSION: In this multicentre crossover simulation study, visible RFM feedback was associated with changes in mask ventilation performance and evidence of a carry-over learning effect following feedback removal. Real-time visibility of respiratory parameters may strengthen neonatal resuscitation training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Respiratory function monitoring during neonatal resuscitation: a crossover study of high-fidelity simulated bronchopulmonary dysplasia.Frontiers in pediatrics · 2026
- Utilizing Low-Dose High-Frequency Simulation Training to Improve Neonatal Mask Ventilation in the Delivery Room.Joint Commission journal on quality and patient safety · 2026
- Prehospital Pediatric Ventilation Quality Following Use of a Feedback Device: A Randomized Study.Pediatrics · 2026
- Real-time feedback during bag-valve-mask ventilation for out-of-hospital cardiac arrest: a before-and-after study (VEntilation during Cardiac Arrest Resuscitation Study, VECARS-2).Resuscitation · 2026
- Distribution of applied forces during face mask ventilation: a preterm neonatal manikin study.Pediatric research · 2026
- Accuracy of ventilation feedback devices compared with a reference standard during asynchronous ventilation with continuous chest compressions in a simulated cardiac arrest: a prospective non-randomized cross-over study.Resuscitation plus · 2026