Evaluation of axial length measurement and other biometric parameters using three different generations of biometers.
Ferdinando Cione, Domenico Mucci, Isabella Pellegrino, Francesco Maria Capuano, Maddalena De Bernardo, Nicola Rosa
Department of Medicine, Surgery and Dentistry, University of Salerno, Salerno, Italy.
Key points
From the paper's conclusion- Therefore, caution should be taken when using these devices interchangeably, especially in longitudinal studies and follow-up evaluations; device-specific interpretation is recommended to optimize refractive outcomes in cataract surgery.
Abstract
PURPOSE: To compare biometric measurements obtained with partial coherence interferometry (IOLMaster 500, IOLM), optical low-coherence reflectometry (Lenstar 900, LS900), and swept-source optical coherence tomography (Eyestar 900, ES900). METHODS: In this prospective, observational study, axial length (AL), anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), and central corneal thickness (CCT) were measured with the three devices. Exclusion criteria were ocular disease, previous ocular surgery, and contact lens use within 72 h. Normality was assessed using the exact Kolmogorov-Smirnov test. Comparisons were performed with paired T-tests and repeated-measures ANOVA with Bonferroni correction. Agreement was evaluated using Bland-Altman plots, and correlation was evaluated using Pearson correlation (r), and intraclass correlation coefficients (ICC). Subgroup analysis by eye side was conducted. RESULTS: Two-hundred-six eyes of 103 healthy subjects (38 females) were recruited at Public hospital "San Giovanni di Dio e Ruggi d'Aragona", Salerno, Italy. All devices showed excellent correlation for AL and ACD (r ≥ 0.947, ICC≥0.939; p < 0.001). AL and ACD were comparable between LS900 and IOLM (ΔAL = +0.00 ± 0.09 mm; ΔACD = +0.01 ± 0.10 mm; p > 0.050). ES900 measured longer AL and deeper ACD than LS900 (ΔAL = +0.03 ± 0.10 mm; ΔACD = +0.04 ± 0.11 mm; p ≤ 0.031) and IOLM (ΔAL = +0.03 ± 0.08 mm; ΔACD = +0.04 ± 0.11 mm; p ≤ 0.013). Strong correlation was observed between ES900 and LS900 for CCT, AD, and LT (r ≥ 0.979, ICC≥0.961; p < 0.001). ES900 measured thicker CCT, deeper AD, and thinner LT (p < 0.017). CONCLUSION: Despite excellent correlation, ES900 provided systematically higher AL and ACD values and different anterior segment measurements. Therefore, caution should be taken when using these devices interchangeably, especially in longitudinal studies and follow-up evaluations; device-specific interpretation is recommended to optimize refractive outcomes in cataract surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Repeatability of an SD-OCT biometer (MS-39 AL) and agreement with a validated biometer (IOLMaster 700).Journal of cataract and refractive surgery · 2026
- Comparison of anterior segment parameters in cataract patients with different axial lengths using IOL Master and Pentacam.BMC ophthalmology · 2026
- Agreement of Anterior Segment Biometrics Measured Using Image-Registered Swept-Source OCT and High-Frequency Ultrasound Biomicroscopy.Journal of glaucoma · 2026
- Correlation Between Lens Density and Inter-Method Difference in Axial Length: Sum-of-Segments Versus Traditional Method on a Novel SS-OCT Biometer and the IOLMaster 700.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Comparison of spectral-domain optical coherence tomography biometry measurements with partial coherence interferometry optical biometryBMC Ophthalmology · 2026
- The Repeatability and Agreement of Two SS-OCT Optical Biometers in Adult Eyes Undergoing Cataract Surgery.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026