Biomechanical effects of supplemental posterior cervical stabilization in one-to three-level anterior cervical discectomy and fusion: a finite element analysis of construct length-dependent stress shielding and adjacent segment mechanics.
Junwei Zhang, Tairui Zhang, Maji Sun, Yang Sun, Shuo Feng, Jun Sun, Feng Yuan
Department of Orthopedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, China. · Department of Orthopedics, Affiliated Hospital of Xuzhou Medical University, Xuzhou, China.
Key points
From the paper's conclusion- One-level ACDF provides sufficient stability. For two-level constructs, posterior fixation offers measurable protection, beneficial for high-risk patients. For three-level constructs, CCF effectively mitigates the significant anterior stress concentration and elevated adjacent disc stress associated with standalone ACDF, despite a minor increase in facet capsule stress. Posterior augmentation should be considered based on construct length.
Abstract
OBJECTIVE: This finite element analysis study aimed to compare the biomechanical behavior of anterior cervical discectomy and fusion (ACDF) with circumferential cervical fusion (CCF) across one-, two-, and three-level constructs, to elucidate the length-dependent contribution of supplemental posterior fixation. METHODS: A C3-C7 finite element model was developed from CT scans. Seven scenarios were simulated: intact spine; 1-, 2-, and 3-level ACDF; and corresponding CCF constructs (ACDF plus bilateral posterior facet cages). A 73.6 N axial load with ±1.0 Nm moments simulated flexion, extension, lateral bending, and axial rotation. Stress on vertebrae, instrumentation, and adjacent segments (C3/4, C5/6, C6/7 facet capsules and discs) was analyzed. RESULTS: The biomechanical benefit of CCF was length-dependent. It reduced anterior plate stress relative to ACDF, with increasing reduction for longer constructs (8%-12% for 1-level, 10%-18% for 2-level, 15%-25% for 3-level). CCF provided greater vertebral stress shielding. All fusions increased adjacent facet capsule stress, slightly more with CCF. However, CCF resulted in lower increases in adjacent disc stress than ACDF (e.g., at C6/7 disc: +1.6% for 3-level CCF vs. +5.8% for ACDF). CONCLUSIONS: One-level ACDF provides sufficient stability. For two-level constructs, posterior fixation offers measurable protection, beneficial for high-risk patients. For three-level constructs, CCF effectively mitigates the significant anterior stress concentration and elevated adjacent disc stress associated with standalone ACDF, despite a minor increase in facet capsule stress. Posterior augmentation should be considered based on construct length.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance-sensitivity analysis of atlantoaxial fixation constructs using finite element modelling.Journal of the mechanical behavior of biomedical materials · 2026
- Influence of anterior plate fixation on axial load-bearing capacity after single-level anterior cervical discectomy and fusion: A biomechanical cadaver study.Clinical biomechanics (Bristol, Avon) · 2026
- Adjacent segment biomechanics after cervical laminectomy and posterior instrumented fusion construct: comparison of C2–T1 and C2–T2 finite element modelsFrontiers in Bioengineering and Biotechnology · 2026
- Facet joint fusion in lumbar surgery: a biomechanical review of posterior column preservation and reconstruction.Frontiers in surgery · 2026
- Comparison of Biomechanics at the Cervicothoracic Junction in C3-6, C3-7, and C2-T2 Constructs: A Parametric, Finite Element Analysis.World neurosurgery · 2026
- Effects of L4-L5 fusion on the adjacent levels in the lumbar spine.Biomedical physics & engineering express · 2026