Performance-sensitivity analysis of atlantoaxial fixation constructs using finite element modelling.
Rahul Singh Dhari, Tiffani Tong, Jessica Gaff, Alana Celenza, Moreica Pabbruwe, Gregory Cunningham, Ian J Davies
School of Civil and Mechanical Engineering, Curtin University, Kent Street, Bentley, WA 6102, Australia. Electronic address: rahul.dhari@curtin.edu.au. · School of Civil and Mechanical Engineering, Curtin University, Kent Street, Bentley, WA 6102, Australia.
Key points
From the paper's conclusion- These findings demonstrate that atlantoaxial fixation performance is governed by a trade-off between absolute stability, stress demand, and sensitivity to cortical and cancellous bone stiffness.
Abstract
Atlantoaxial instability (AAI) is commonly treated using posterior fixation constructs that restrict relative C1-C2 motion and promote fusion. Although transarticular screw fixation, Goel-Harms screw-rod fixation, and combined fixation are established clinically, their relative biomechanical performance is often assessed primarily through displacement or range of motion reduction. The present study develops a three-dimensional finite element (FE) model of the C1-C2 segment and introduces a performance-sensitivity framework to evaluate fixation stability, implant stress demand, and robustness to bone-property variation. The model was benchmarked against published numerical and experimental data for intact and instrumented configurations. Flexion, extension, lateral bending, and axial rotation were simulated using a 1.5 N⋅m moment and a 40 N compressive preload. Cortical and cancellous elastic moduli were systematically varied to quantify displacement sensitivity, stress sensitivity, and an overall performance-sensitivity score for each construct. At the reference material condition, the combined construct provided the greatest reduction in relative C1-C2 displacement and generally produced the lowest peak construct stresses. However, the sensitivity analysis showed that the most stable construct was not necessarily the least sensitive to bone-property variation. The Goel-Harms construct exhibited lower material sensitivity in several loading cases, but this occurred at higher absolute displacement and stress levels. Increasing cancellous stiffness generally reduced displacement and construct stress, whereas increasing cortical stiffness reduced displacement but often increased construct stress, indicating increased implant stress demand. These findings demonstrate that atlantoaxial fixation performance is governed by a trade-off between absolute stability, stress demand, and sensitivity to cortical and cancellous bone stiffness. The proposed framework provides a mechanics-based basis for interpreting fixation behaviour beyond conventional displacement-based comparison.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical comparison of seven occipital-cervical fixation constructs using finite element modeling.Journal of craniovertebral junction & spine · 2026
- Biomechanical effects of supplemental posterior cervical stabilization in one-to three-level anterior cervical discectomy and fusion: a finite element analysis of construct length-dependent stress shielding and adjacent segment mechanics.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical Comparison of Three Fixation Constructs for Tile Type C1.2 Pelvic Ring Fractures: A Finite Element AnalysisLife · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion.Global spine journal · 2026