Adjacent segment biomechanics after cervical laminectomy and posterior instrumented fusion construct: comparison of C2–T1 and C2–T2 finite element models
Balaji Harinathan, Febin Chris Asir J. A, Aju Bosco, Karthik Banurekha Devaraj, Davidson Jebaseelan, Narayan Yoganandan
Key points
From the paper's conclusion- The findings show level- and loading-dependent changes rather than uniformly higher adjacent-segment responses.
Abstract
Objective Cervicothoracic finite element (FE) models ending at T1 can introduce boundary condition artifacts at the cervicothoracic junction (CTJ) for cervical laminectomy and posterior instrumented fusion (CLPIF) constructs in the caudal region. This study assessed whether extending the model to T2 changes postoperative adjacent-segment mechanics. Methods Anatomically detailed C2–T1 and rib-supported C2–T2 FE models were evaluated under 2.0 Nm flexion and extension. C4–C7 CLPIF was evaluated in both model extents, with an additional C4–T1 construct in the C2–T2 model. Segmental range of motion (ROM), intradiscal pressure (IDP), and capsular ligament strain (CLS) were compared with the corresponding intact conditions. C2–T2 IDP and CLS were reported as peak spatial 95th-percentile values. Results Rib support reduced the combined intact T1–T2 flexion–extension ROM by 29.5%, close to the approximately 28.0% literature target. After C4–C7 CLPIF, ROM in the rib-supported C2-T2 model increased by 32.4% in flexion and decreased by 1.3% in extension at C3–C4; the increases at C7–T1 were 4.4% and 6.0%, respectively. Flexion IDP decreased at C3–C4 but increased at C7–T1, while CLS increased at both levels. Extending the fusion to T1 reduced C7–T1 ROM, but T1–T2 IDP and CLS remained above intact values. Conclusion Extending the cervical spine model through T2 permits evaluation of T1–T2 mechanics and CLPIF constructs ending at C7 or T1. The findings show level- and loading-dependent changes rather than uniformly higher adjacent-segment responses. Including T2 may support the evaluation of caudal cervical constructs, but these computational findings provide modeling guidance rather than direct evidence for clinical endpoint selection. Future studies may validate the model before clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anterior transcorporeal approach percutaneous endoscopic cervical discectomy for two-segment cervical disc herniation treatment: a finite element analysisBMC Musculoskeletal Disorders · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Comparison of Biomechanics at the Cervicothoracic Junction in C3-6, C3-7, and C2-T2 Constructs: A Parametric, Finite Element Analysis.World neurosurgery · 2026
- A Review of Motion-Preserving Cervical Spinal Implants and Fusion ConstructsBioengineering · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Design and biomechanical validation of a zero-profile self-stabilizing 3D-printed titanium mesh cage for anterior cervical corpectomy and fusionFrontiers in Bioengineering and Biotechnology · 2026