Three-dimensional finite element analysis of translaminar lag screw designs for L5 bilateral spondylolysis.
Feng Li, Xingguo Tan, Tao Zhang, Hua Liu, Songkai Li
Department of Spine Surgery, The 940th Hospital of Joint Logistic Support Force of Chinese People's Liberation Army, Lanzhou, Gansu, China.
Key points
From the paper's conclusion- All translaminar lag screw designs can effectively restore stability in L5 spondylolysis. While different diameters and structural designs have a minor impact on stability restoration, they significantly affect implant stress. In this specific patient-derived model, the 4.5 mm solid screw demonstrated the most favorable biomechanical profile, with the lowest stress on the implant and effective control of graft displacement. These findings suggest a potential mechanical advantage for 4.5 mm solid screws; however, confirmation through multi-specimen studies or clinical trials is required before broader clinical recommendations can be made.
Abstract
PURPOSE: This finite element study aimed to quantitatively compare the biomechanical properties of translaminar lag screws with different diameters and structural designs for the surgical repair of L5 bilateral spondylolysis, to provide evidence for individualized screw selection. METHODS: An intact model of L4-S1 segment (Model A) and a L5 bilateral spondylolysis model (Model B) were established using Mimics, Geomagic, and SolidWorks. Additional models were constructed incorporating translaminar lag screws of varying diameters: 4.5 mm (solid, Model C1; cannulated, Model C2), 4.0 mm (solid, Model D1; cannulated, Model D2), and 3.5 mm (solid, Model E1; cannulated, Model E2). Following model validation, a 400 N axial load and a 10 N m moment were applied to simulate five conditions. Analyzed parameters included range of motion (ROM), maximum displacement, and maximum von Mises stress in the disc, pars interarticularis, and fixation screws. RESULTS: Compared to the intact model (A), the spondylolysis model (B) showed significant instability. All fixation models (C1-E2) effectively restored ROM to intact levels, regardless of screw diameter or structural design. Larger-diameter (4.5 mm) and solid designs demonstrated slightly better control of model displacement. Increasing diameter significantly reduced stress concentrations within the pars interarticularis and fixation screws. For a given diameter, cannulated screws sustained higher stress than solid screws. The 3.5 mm cannulated screw exhibited the highest screw stress, approaching the yield strength of titanium alloy under rotational loading. CONCLUSION: All translaminar lag screw designs can effectively restore stability in L5 spondylolysis. While different diameters and structural designs have a minor impact on stability restoration, they significantly affect implant stress. In this specific patient-derived model, the 4.5 mm solid screw demonstrated the most favorable biomechanical profile, with the lowest stress on the implant and effective control of graft displacement. These findings suggest a potential mechanical advantage for 4.5 mm solid screws; however, confirmation through multi-specimen studies or clinical trials is required before broader clinical recommendations can be made.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Finite element analysis of a novel repair device for lumbar spondylolysis.BMC musculoskeletal disorders · 2026
- Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.BMC musculoskeletal disorders · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Biomechanical analysis of T10-T11 vertebrae under the combined effects of osteoporosis and L4 spondylolisthesis: a finite element analysis based on computed tomography.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study.BMC musculoskeletal disorders · 2026