Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.
Hanqiang Liu, Yuliang Xie, Hongtao Hu, Jianwei Sun, Aijun Yang, Sishun Zhao, XiuRong Wang, Hongbo Liu,
Department of Spinal Surgery, Affiliated Hospital of Shandong Second Medical University, Weifang, Shandong, China. · Department of Operating Room, Affiliated Hospital of Shandong Second Medical University, Weifang, Shandong, China.
Key points
From the paper's conclusion- From a biomechanical perspective, the UBE‑IDO surgery exerts a relatively minor impact on the lumbar spine. ULIF provides a more favorable biomechanical environment for intervertebral fusion. In the fusion model, Endo-TLIF provides a relatively favorable biomechanical environment for the internal fixation. Among the three fusion models, ULIF has the least impact on the biomechanics of adjacent segments. The absolute stress values presented herein are intended only for hypothesis generation, and inferences should be limited to relative trends among surgical models under identical assumptions.
Abstract
BACKGROUND: This study aimed to analyze and compare the biomechanical effects of four different minimally invasive surgical procedures for lumbar spinal stenosis complicated by degenerative spondylolisthesis. METHODS: A static finite element analysis was performed using data from a single healthy volunteer. A validated three-dimensional L1-S1 finite element model was constructed from CT scans of a 26‑year‑old healthy adult male. Based on the health model, the following finite element models were created: lumbar spinal stenosis with degenerative spondylolisthesis (LSS-DS), unilateral biportal endoscopy with ipsilateral decompression only (UBE‑IDO), unilateral biportal endoscopy lumbar interbody fusion (ULIF), minimally invasive transforaminal lumbar interbody fusion (Mis-TLIF), and endoscopic transforaminal lumbar interbody fusion (Endo-TLIF). Using the Hyperwork software, flexion-extension, lateral bending and lateral rotation loading conditions were simulated to compare the biomechanical effects among the models. RESULTS: Compared with the LSS-DS, the UBE‑IDO model showed changes in peak von Mises stress of the L4-L5 intervertebral disc and articular cartilage not exceeding 0.21 MPa. The ULIF model exhibited the highest bone graft stress among the fusion groups. Under the left lateral rotation, the Mis-TLIF demonstrated the highest peak von Mises stress in the internal fixation system(113.62 MPa). Under the right lateral bending, the Mis-TLIF showed the highest cage peak von Mises stress(25.12 MPa). Under the flexion, extension, and rotation, the peak von Mises stress of the L5-S1 articular cartilage in the Endo-TLIF group was the highest. Under the left bending and right rotation conditions, the Mis-TLIF had the highest peak von Mises stress at the L5-S1 articular cartilage. CONCLUSIONS: From a biomechanical perspective, the UBE‑IDO surgery exerts a relatively minor impact on the lumbar spine. ULIF provides a more favorable biomechanical environment for intervertebral fusion. In the fusion model, Endo-TLIF provides a relatively favorable biomechanical environment for the internal fixation. Among the three fusion models, ULIF has the least impact on the biomechanics of adjacent segments. The absolute stress values presented herein are intended only for hypothesis generation, and inferences should be limited to relative trends among surgical models under identical assumptions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical comparison of stand-alone interbody bone grafting versus cage implantation in ULIF: a finite element analysisScientific Reports · 2026
- Effects of L4-L5 fusion on the adjacent levels in the lumbar spine.Biomedical physics & engineering express · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Biomechanical Comparison of Unilateral Biportal Endoscopy and Percutaneous Endoscopic Lumbar Discectomy Using a Finite Element ModelJOR SPINE · 2026
- Three-dimensional finite element analysis of translaminar lag screw designs for L5 bilateral spondylolysis.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026