Investigating the Performance of Rehabilitated Non-Prismatic Reinforced Concrete Columns Subjected to Cyclic Load
Romaih O. Mostafa, Sofyan Y. Ahmed, Jasim A. Abdullah
Key points
From the paper's conclusion- The cyclic performance and post-damage rehabilitation of non-prismatic reinforced concrete columns, remain insufficiently characterized.
Abstract
The cyclic performance and post-damage rehabilitation of non-prismatic reinforced concrete columns, remain insufficiently characterized. This study investigates the axial, pushover, and cyclic behaviour of non-prismatic RC columns and evaluates two rehabilitation techniques-ferrocement jacketing and steel-plate jacketing-applied after yield-level damage. Eight non-prismatic columns were fabricated and tested. Two control specimens were loaded axially to failure to establish load-carrying capacity; two underwent pushover testing at 20% and 40% axial load ratios to determine yield displacement; and four were subjected to yield-level reversed cyclic loading to induce controlled permanent deformation, then repaired with a 25 mm ferrocement jacket or a 2.71 mm steel-plate jacket and retested under quasistatic cyclic protocol. The columns achieved an average axial capacity of 905 kN and failed in shear at the necking region. Increasing the axial loading ratio from 20% to 40% reduced the yield displacement from 7.35 mm to 5.7 mm (22.5%) and lowered dissipated hysteretic energy by approximately 21%, while increasing lateral strength by 86%. Both rehabilitation techniques effectively restored strength and stiffness: steel jacketing delivered partial stiffness recovery and higher performance levels, whereas ferrocement delivered full stiffness recovery and dissipated marginally more energy (9% higher at 20% axial load). Increasing the sustained load from 20% to 40% narrows the difference of the total energy dissipated in both types of rehabilitation. Steel jacketing is the preferable choice where residual-drift control is the governing design criterion, while ferrocement remains a viable, more economical alternative where moderate ductility demand and lower axial load ratios are expected.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Investigation of Retrofitting Strategies for Existing Reinforced Concrete Beam-Column Joints: A Systematic ReviewInternational Journal for Research in Applied Science and Engineering Technology · 2026
- Retrofitting damaged subway station columns with CFRP grid-reinforced ECC jackets for improved seismic performanceEngineering Structures · 2025
- Effect of jacket configuration and anchorage in hybrid strain hardening cementitious composites with steel mesh strengthening of reinforced concrete beamsScientific Reports · 2025
- Cyclic Bond Behavior of Deformed Bars in Modified Crumb Rubber Concrete with Nano-Silica and Steel Fiber: An Experimental StudyIOP Conference Series: Earth and Environmental Science · 2026
- Behaviour of Pre-Damaged Concrete Columns with Different Geometries Retrofitted by using CFRPIOP Conference Series: Earth and Environmental Science · 2026
- Cyclic tensile behavior and component‐based modeling of box connections in prefabricated concrete elevator shafts for retrofitting old dwellingsStructural Concrete · 2026