Cyclic tensile behavior and component‐based modeling of box connections in prefabricated concrete elevator shafts for retrofitting old dwellings
Bo Xu, Yanyan Wan, Zhijun Cheng, Jianjun Wei, Yimin Lu, M. D. Taufiq Ahmed
Key points
From the paper's conclusion- In the present study, a series of monotonic and cyclic tensile tests, finite‐element simulations considering several design parameters, and component‐based theoretical modeling were conducted on the box connections.
Abstract
An innovative prefabricated concrete elevator‐shaft system with a prestressing‐box hybrid connection was developed for old dwelling renovation to achieve rapid installation and reliable seismic performance. However, as the key connecting components in prefabricated constructions, the mechanical performance and mechanism of box connections have not been fully understood. In the present study, a series of monotonic and cyclic tensile tests, finite‐element simulations considering several design parameters, and component‐based theoretical modeling were conducted on the box connections. Results indicated that the anchor rod governed load transfer and energy dissipation through elastic–plastic deformation, whereas the box plates and longitudinal reinforcement provided auxiliary confinement and load sharing. Specimens with 20 mm anchor rods exhibited stable hysteresis loops and superior ductility, confirming their suitability for mechanical retrofitting applications. It was obtained that the bearing capacity and stiffness of box connections under cyclic uniaxial tension decreased significantly due to the Bauschinger effect and cyclic accumulative plastic damage. Parametric analyses revealed that anchor‐rod diameter, yield strength, and box‐plate thickness were the dominant factors affecting stiffness, strength, and energy dissipation, while rod length and wall‐bar diameter had negligible influence. A component‐based spring model was developed and the bilinear constitutive formulation was established, which accurately reproduced the load–displacement curves and provided the foundation for engineering design for box connection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental investigation of seismic performance of reinforced concrete beam‐column joints with hybrid connections combining friction side plates and composite energy‐dissipation boxesStructural Concrete · 2026
- Experimental study on seismic performance of prefabricated reinforced concrete beam–column jointsStructures · 2026
- Study on tensile–shear damage of concrete post‐installed threaded rod specimenStructural Concrete · 2026
- Investigation of a Self-Centring Beam-to-Beam Connection and Its Structure-Level Seismic ResponseBuildings · 2026
- Study on the plastic hinge relocation mechanism in a novel precast post‐tensioned beam‐to‐column jointStructural Concrete · 2026
- Seismic performance of prefabricated reinforced concrete joints with embedded steel plate welding connectionStructural Concrete · 2026