Effect of jacket configuration and anchorage in hybrid strain hardening cementitious composites with steel mesh strengthening of reinforced concrete beams
Abdulaziz Alaskar, Arsalan Mahmoodzadeh, Galal Elsamak, Yahia Iskander, Ramy I. Shahin, Mohamed Ghalla
King Saud University · Tarbiat Modares University
Key points
From the paper's conclusion- These findings clearly demonstrate the necessity and effectiveness of the proposed retrofit system for extending the service life and resilience of RC beams.
Abstract
Reinforced concrete (RC) structures often need shear retrofit due to factors like design deficiencies, aging, or increased loads. This study explores an innovative hybrid retrofit system for RC beams with shear defects, using an external jacket composed of strain-hardening cementitious composites (SHCC) and welded steel mesh (WSM). An experimental program including nine RC beams, involving control, defected, and strengthened specimens, was prepared to assess the effectiveness of many jacket arrangements (one-sided, two-sided, U-wrapped, and fully wrapped) and the influence of mechanical anchorage. In addition, the experimental work was simulated using Abaqus program to replicate the beams' behavior. Experimental findings showed that the shear defect significantly reduced load capacity, stiffness, and energy absorption. All strengthening configurations improved performance, with effectiveness generally increasing from one-sided to full wrapping. Anchorage bolts enhanced load capacity and energy absorption, particularly for partial jackets and U-wraps. Particularly, the fully wrapped configuration restored the beam's ultimate load capacity nearly to the level of the control beam, even without anchorage, and significantly enlarged absorbed energy. The FE model accurately simulated the experimental failure modes, crack patterns, and load-displacement responses, validating its reliability. Full jacketing with anchorage improved the ultimate load capacity by up to 75% compared to unstrengthened beams. Crack propagation was considerably delayed, and average crack widths were reduced by 30-35%. Moreover, the retrofitted beams exhibited a remarkable increase in energy absorption capacity, achieving up to 3.8 times the energy dissipation of the control specimens. These findings clearly demonstrate the necessity and effectiveness of the proposed retrofit system for extending the service life and resilience of RC beams.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- External near-surface mounted steel wire wrapping for shear enhancement of reinforced concrete beamsResults in Engineering · 2026
- Flexural Performance Evaluation of RC Beams Strengthened with Cementitious Composites under Static and Fatigue Loading: A Comprehensive ReviewInternational Journal of Concrete Structures and Materials · 2026
- Strengthening of punching shear of flat slab–column connections through hybrid near‐surface mounted and externally bonded systems: Experimental, numerical, and analytical studyStructural Concrete · 2026
- Flexural Capacity Calculation Method for Pre-Damaged RC Beam-Column Joints Strengthened with High-Strength Steel Strand Mesh-Reinforced ECC.Materials (Basel, Switzerland) · 2026
- Seismic performance of reinforced concrete beam column joints strengthened with ECC shellsScientific Reports · 2026
- Arch action and beam action in reinforced engineered cementitious composite (ECC) beams subjected to shearEngineering Structures · 2026