Behaviour of Pre-Damaged Concrete Columns with Different Geometries Retrofitted by using CFRP
Pooja Lohchab, Mehtab Alam, Taraka M. R. Balla
Key points
From the paper's conclusion- Thus, the present study evaluates the influence of column geometry, edge chamfering, and damage level on strength performance enhancement in terms of load-carrying capacity.
Abstract
Columns are the vital load-carrying elements in framed structures. Retrofitting of existing concrete columns has become essential due to aging infrastructure, increased service loads, and seismic performance deficiencies. However, existing research studies on strengthening pre-damaged columns are limited. This study experimentally investigates the efficiency of a rehabilitation of pre-damaged plain concrete short compression members with different cross-sectional geometries using carbon fibre–reinforced polymer (CFRP) wrapping. In the study, circular, square, and chamfered-square plain concrete specimens were cast with M20 grade concrete and tested under axial compression. The specimens were categorised into five groups for each geometry, including reference columns, confined undamaged columns, and pre-damaged columns subjected to 55%, 65% and 75% of the reference ultimate load prior to CFRP strengthening. Thus, the present study evaluates the influence of column geometry, edge chamfering, and damage level on strength performance enhancement in terms of load-carrying capacity. The Load-displacement response of chamfered square confined undamaged, and partially damaged specimens shows promising improvements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CFRP-Confined Pre-Damaged Recycled Aggregate Concrete Square Columns Under Axial CompressionApplied Sciences · 2026
- Axial Compressive Behaviour of Intermediate-Length Concrete-Filled Steel Tubular Columns with Different CFRP Wrapping ConfigurationsBuildings · 2026
- Behavior of FRP‐Reinforced Concrete Columns Subjected to Combined Axial Compression and Lateral LoadingAdvances in Civil Engineering · 2026
- Post-repair behaviour of seismically damaged precast GFRP-RC columns retrofitted with CFRP wrapsConstruction and Building Materials · 2025
- Influence of connection type on the effectiveness of CFRP wraps in seismic repair of precast GFRP-reinforced concrete columnsEngineering Structures · 2026
- Retrofitting damaged subway station columns with CFRP grid-reinforced ECC jackets for improved seismic performanceEngineering Structures · 2025