The accuracy of VO2 max, heart rate and energy expenditure measurements from Google Pixel Watch 3.
Rory Lambe, Moritz Schumann, Sherene Hamilton, Lauren Donnelly, Thomas White, Seán O'Reilly, Saoirse Lally, Cailbhe Doherty
School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin, Ireland. · School of Medicine and Health, Experimental Exercise Science, Technical University of Munich, Munich, Germany.
Key points
From the paper's conclusion- Here, we evaluated the validity of VO2max, heart rate and energy expenditure from the Google Pixel Watch 3.
Abstract
Consumer wearables enable scalable physiological assessment and pre-symptomatic disease detection. However, validation of wearable data remains insufficient in scope and rigour, hindering integration into clinical and public health practice. Here, we evaluated the validity of VO2max, heart rate and energy expenditure from the Google Pixel Watch 3. Thirty-four participants completed a maximal exercise treadmill test using indirect calorimetry, while wearing a Polar H10 chest strap. Pixel Watch estimates of VO2max were generated in free-living conditions; heart rate and energy expenditure estimates were recorded during exercise testing. Bland-Altman analysis showed low bias but wide limits of agreement for VO2max estimates from the Pixel Watch 3 (bias -0.53 mL/kg/min; limits of agreement [LoA] -12.56 to 11.50; mean absolute percentage error [MAPE] 8.65%). Heart rate demonstrated strong agreement with the criterion overall, despite measurement variability (bias -2.39 bpm; LoA -24.42 to 19.65; MAPE 2.73%). The error for energy expenditure varied substantially between participants (bias -8.43 kcal; LoA -72.75 to 55.88; MAPE 15.02%). These results indicate that VO2max estimates lack sufficient individual-level validity for clinical use, although the bias suggests utility for population health monitoring. Heart rate showed acceptable error for exercise monitoring, whereas the large variation in error for energy expenditure limits its practical use. Our findings illustrate that wearable data require condition- and population-specific validation before incorporation into health care pathways.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Associations of Google Pixel Watch 3 Daily Readiness with Autonomic Physiology and Self-Reported Wellness: An Exploratory 14-Day Repeated-Measures Study.Sensors (Basel, Switzerland) · 2026
- Accuracy of Optical Heart Rate Measurements for 10 Commercial Wearables in Different Climate Conditions and Activities: Instrument Validation StudyJMIR Formative Research · 2026
- Criterion Validity of Smartwatches for Measuring Heart Rate and Energy Expenditure During Resistance Exercise.Bioengineering (Basel, Switzerland) · 2026
- Remote monitoring of heart failure exacerbations using a smartwatchNature Medicine · 2026
- Agreement of consumer wearable pulse oximeters across activity conditions and skin pigmentation.Frontiers in digital health · 2026
- Evaluation of Blood Pressure and Heart Rate Measurements from Smartwatch HUAWEI WATCH D2 Data: A Preliminary Report.Healthcare (Basel, Switzerland) · 2026