Valve-in-valve transcatheter mitral valve replacement via totally endoscopic endoclamp-assisted approach after failed bioprosthetic mitral valve: a case report.
J Nader, A Roussiaux, J E Ricci, C Piot
Department of Cardiac Surgery, Clinique du Millénaire, Montpellier, France. dr.joseph.nader@gmail.com. · Department of Cardiac Surgery, Clinique du Millénaire, Montpellier, France.
Key points
From the paper's conclusion- A 29 mm SAPIEN 3 Ultra transcatheter heart valve was therefore deployed inside the surgical frame under direct vision on cardiopulmonary bypass (CPB).
Abstract
Endoscopic Endoclampassisted MViV can expand the armamentarium for complex redo mitral surgery, offering excellent early clinical and haemodynamic results in selected patients. A 50 year-old man with heavy alcohol and tobacco use and two previous mitral operations (repair, then bioprosthetic replacement eight years earlier) presented with progressive dyspnoea (NYHA III). Transthoracic and transoesophageal echocardiography revealed severe mixed stenosis/regurgitation of a 33 mm Medtronic Mosaic bioprothesis. No endocarditis was found preoperatively. After shared decisionmaking, minimally invasive videoassisted right minithoracotomy under endoaortic balloon occlusion (Endoclamp®) was planned. Intraoperatively, the degenerated valve was firmly embedded in the native annulus and could not be safely explanted. A 29 mm SAPIEN 3 Ultra transcatheter heart valve was therefore deployed inside the surgical frame under direct vision on cardiopulmonary bypass (CPB). Postdeployment echocardiography showed a mean gradient of 8 mmHg without paravalvular leak or LVOT compromise. The patient was extubated on postoperative day 2; aside from temporary difficulties in respiratory weaning, recovery was uneventful, and he was discharged home on day 9.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Double-Anchoring Transcatheter Mitral Valve Replacement: A Case Report of Septal Capture of Embolized Transcatheter Mitral Valves.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Simultaneous Aortic and Mitral Valve-in-Valve Replacement Using Balloon-Expandable MyVal Valves With Bioprosthetic Valve Fracture.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Salvage Transcatheter Mitral Valve-in-Valve With Aspiration Thrombectomy in a Young Adult With Repaired CHD.JACC. Case reports · 2026
- Retrograde Mitral Paravalvular Leak Closure Through a Mechanical Aortic Prosthesis After Failed Antegrade Access.JACC. Case reports · 2026
- Double-Port Totally Endoscopic Mitral Valve Replacement Through a Prosthesis-Sized Working Incision with Posterior Subvalvular Preservation.Journal of the Saudi Heart Association · 2026
- Avoiding Resternotomy: Minimally Invasive Redo Mitral Valve Surgery in a Two-Center Series.Journal of clinical medicine · 2026