Key points
From the paper's conclusion- We report a high-risk 63-year-old woman with severe recurrent mitral regurgitation after minimally invasive repair who underwent a staged, image-guided transcatheter strategy.
Abstract
Transcatheter mitral valve replacement (TMVR) after failed surgical repair with an incomplete annuloplasty ring remains technically challenging because the absence of anterior support compromises anchoring. We report a high-risk 63-year-old woman with severe recurrent mitral regurgitation after minimally invasive repair who underwent a staged, image-guided transcatheter strategy. A PASCAL Ace device (Edwards Lifesciences) was implanted at the medial commissure to augment the landing zone, followed by balloon atrial septostomy and antegrade LAMPOON (Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction). Initial deployment of a 29-mm SAPIEN 3 Ultra valve (Edwards Lifesciences) produced a severe skirt leak, and valve-in-valve implantation resulted in embolization of both prostheses into the left atrium with cardiogenic shock. After emergent venoarterial extracorporeal membrane oxygenation, a third overfilled SAPIEN 3 Ultra valve was secured in the mitral position. The embolized valves were then immobilized against the interatrial septum using a 38-mm Amplatzer Septal Occluder (Abbott). This case demonstrates double-anchoring TMVR and septal capture as a feasible percutaneous bailout in complex failed-repair mitral anatomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Valve-in-valve transcatheter mitral valve replacement via totally endoscopic endoclamp-assisted approach after failed bioprosthetic mitral valve: a case report.Journal of cardiothoracic surgery · 2026
- Expanding TMVR Suitability with a Transseptal Left Atrial Fixation Device: A CT-based Eligibility AnalysisEuropean Heart Journal · 2026
- Transcatheter Mitral Valve-in-Valve Replacement Complicated by Valve Embolization: Percutaneous Rescue With a Double-Rail Technique.JACC. Case reports · 2026
- Guide-sheath-assisted bailout technique for intra-procedural single-leaflet device attachment using the PASCAL system: a case report.European heart journal. Case reports · 2026
- Outcomes of rescue procedures in patients undergoing unsuccessful deployment of transcatheter mitral valve replacement.Journal of cardiothoracic surgery · 2026
- Double Transeptal Puncture for SAPIEN M3 Transcatheter Mitral Valve Replacement: Initial Experience, Indications, and Technique.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026