Retrograde Mitral Paravalvular Leak Closure Through a Mechanical Aortic Prosthesis After Failed Antegrade Access.
Bengisu Sahin, Kumral Cagli, Derya Tok, Huseyin Bozbas
Department of Cardiology, TOBB University of Economics and Technology Faculty of Medicine Hospital, Ankara, Türkiye. · Department of Cardiology, Ankara Bilkent City Hospital, Ankara, Türkiye.
Key points
From the paper's conclusion- We then passed through the central orifice of her bileaflet mechanical aortic valve and crossed the leak from the ventricular side.
Abstract
BACKGROUND: Mitral paravalvular leak can cause heart failure and hemolysis after valve replacement. Transcatheter closure is an option when repeat surgery carries high risk. CASE SUMMARY: A 66-year-old woman with mechanical valves in both the aortic and mitral positions had a symptomatic, approximately 5-mm posterior mitral leak. We first attempted transseptal closure but could not cross the defect. We then passed through the central orifice of her bileaflet mechanical aortic valve and crossed the leak from the ventricular side. An 8-mm Amplatzer Vascular Plug II was deployed through a 5-F delivery system. Valve function was preserved, and follow-up imaging showed no significant residual leak. DISCUSSION: The position and small size of the leak, the bileaflet aortic prosthesis, and the low-profile delivery system made this route feasible in this patient. TAKE-HOME MESSAGE: Retrograde access may be useful after failed antegrade crossing, even in the presence of a mechanical aortic valve.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful Transcatheter Amplatzer Repair of Severe Paravalvular Leak Following Mechanical Mitral Valve Replacement Surgery.Case reports in cardiology · 2026
- Valve-in-valve transcatheter mitral valve replacement via totally endoscopic endoclamp-assisted approach after failed bioprosthetic mitral valve: a case report.Journal of cardiothoracic surgery · 2026
- Transcatheter Mitral Paravalvular Leak Closure With a Multifunctional Ventricular Septal Defect Occluder.JACC. Case reports · 2026
- Right internal jugular approach for transcatheter edge-to-edge mitral valve repair using the MitraClip G4 system after failed transfemoral access: a case report.European heart journal. Case reports · 2026
- Transcatheter Mitral Valve Replacement in an Incomplete Ring With LAMPOON Facilitated By Aortic Prosthesis.JACC. Case reports · 2026
- Leaflet Perforation During Mitral Transcatheter Edge-to-Edge Repair: A Stepwise Dual-Device Strategy Leveraging Valve Geometry Modification.JACC. Case reports · 2026