Investigation of the biomechanical properties of circular frames for the foot
Sarah Johnson-Lynn, Tom Irish, Peter Watson, Paul Harwood, Todd Stewart
Key points
From the paper's conclusion- The results of this study have important clinical implications, specifically with regards weightbearing instructions given to patients living with a frame.
Abstract
Circular frames are used for the treatment of complex foot injuries, including those with bone and soft tissue loss and deformities requiring gradual correction. The most frequently used foot frames are a Charcot frame, a Butt frame and a Mitre frame. The aim of this study was to provide data on the biomechanical properties of these frames under a simulated axial load. This will provide surgeons with information to assist in selecting the most appropriate frame for a given circumstance and will facilitate further biomechanics research in this developing area. Four frame fixation model geometries were constructed using Orthofix TL-HEX components. 3D foot models for use in the study were manufactured using 3D printing. The Charcot frame showed the least stiffness throughout the range of load applied with a stiffness increasing from 31 N/mm at 50 N load to 93 N/mm at a load of 700 N, whereas the Butt frame generally produced the greatest construct stiffness increasing from 47 N/mm at 50 N load to 122 N/mm at a load of 700 N. The Mitre frame had the greatest initial stiffness of 53 N/mm at 50 N but it only increased to 105 N/mm at 700 N. The Charcot frame presents the lowest resistance to axial loading of all the common constructs, which has implications for its use in patients with higher body mass index and peripheral neuropathy. The results of this study have important clinical implications, specifically with regards weightbearing instructions given to patients living with a frame.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Force measurement in circular external fixation frames reflects construct stability: A laboratory proof-of-concept study.Injury · 2026
- Finite Element Analysis of the Foot and Ankle: A Critical Review of Metatarsal Biomechanics, Hallux Valgus, Fixation, and Plantar LoadingBiomechanics · 2026
- Internal Fixation Bone Mass Index (IFBM) and Biomechanical Performance of Different Fixation Methods for Herscovici Type B and Type C Medial Malleolar Fractures.The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2026
- Biomechanical Comparison of Three Fixation Constructs for Tile Type C1.2 Pelvic Ring Fractures: A Finite Element AnalysisLife · 2026
- Intraarticular calcaneal fractures: biomechanical analysis of two fixation constructs.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- Biomechanical Evaluation of Crossed Screw Fixations With Different Head Designs for First Tarsometatarsal Joint Arthrodesis.Foot & ankle specialist · 2026