Biomechanical Evaluation of Crossed Screw Fixations With Different Head Designs for First Tarsometatarsal Joint Arthrodesis.
Joachim Ortmayr, Emir Benca, Tamás Dornyi, Lena Hirtler, Andrea Veljkovic, Reinhard Schuh, Shahin Zandieh, Reinhard Windhager,
Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria. · Center of Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria.
Key points
From the paper's conclusion- We compared the biomechanical properties of conventional and headless compression screws in a modified Lapidus first tarsometatarsal joint (TMTJ) arthrodesis model.MethodsTen matched human lower extremity pairs were randomly assigned to first TMTJ arthrodesis using either 2 crossed headed 4.0-mm cannulated compression screws (HS) or two 4.0-mm cannulated headless compression screws (HLS).
Abstract
BackgroundMidfoot arthrodesis is used to treat deformity, instability, and degenerative conditions. Headless compression screws may reduce hardware prominence and soft tissue irritation. We compared the biomechanical properties of conventional and headless compression screws in a modified Lapidus first tarsometatarsal joint (TMTJ) arthrodesis model.MethodsTen matched human lower extremity pairs were randomly assigned to first TMTJ arthrodesis using either 2 crossed headed 4.0-mm cannulated compression screws (HS) or two 4.0-mm cannulated headless compression screws (HLS). After bone mineral density (BMD) assessment, specimens were cyclically loaded from 0 to 31 N for 1000 cycles. Dorsal angulation and construct stiffness were measured during cyclic loading and subsequent loading to failure.ResultsMean stiffness during ultimate load testing was 58.91 ± 31.33 N/mm for headed screws and 68.36 ± 84.29 N/mm for headless screws (P = .842). Mean yield load was 115.80 ± 61.94 and 67.79 ± 35.90 N (P = .101), and mean ultimate load was 142.10 ± 65.24 and 83.02 ± 60.77 N (P = 0.064), respectively. No significant difference in dorsal angulation was observed. Mean BMD was 0.547 ± 0.222 g/cm² for headed screws and 0.533 ± 0.204 g/cm² for headless screws (P = 0.897). Bone mineral density positively correlated with construct stiffness in the headless screw group during several loading cycles, but not in the headed screw group. No significant correlations were found between BMD and yield or ultimate load.ConclusionHeaded and headless crossed screw constructs showed no statistically significant differences in stiffness, yield load, ultimate load, or dorsal angulation. However, the numerical difference in ultimate load favored headed screws. Headless compression screws may offer clinical advantages through their low-profile design, but further biomechanical and clinical studies are warranted.Clinical Relevance:Headless and headed screws showed no statistically significant differences in this cadaveric first tarsometatarsal joint model, although headed screws achieved higher mean failure loads. Their low-profile design may reduce hardware prominence and soft tissue irritation while maintaining adequate primary fixation stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determinants of Sagittal Alignment Following First Metatarsophalangeal Arthrodesis: The Influence of Native Anatomy, Fixation Construct, and Surgeon Experience.Journal of clinical medicine · 2026
- Methods for Biomechanical Testing of Fifth Metatarsal Fracture Fixation: A Scoping Review.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026
- Comparison of 3 Headless Compression Screw Types for Proximal, Waist, and Distal Scaphoid Fractures.Hand (New York, N.Y.) · 2026
- High reoperation rates following first metatarsophalangeal joint arthrodesis using a modern compression plating system with a retrograde integrated lag screw.Foot (Edinburgh, Scotland) · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Biomechanical comparison of parallel versus convergent screw fixation in Zadek osteotomy.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026