Internal Fixation Bone Mass Index (IFBM) and Biomechanical Performance of Different Fixation Methods for Herscovici Type B and Type C Medial Malleolar Fractures.
Ying Zhang, Zhenjun Zhang, Pan Hao, Bin Li, Zhaorui Liu
Department of Orthopedic Surgery, Central Hospital Affiliated to Shandong First Medical University, Jinan 250013, Shandong, China. · Architectural Branch of Jinan Design Institute, China Railway Engineering Consulting Group Co., Ltd., Jinan 250022, Shandong, China.
Key points
From the paper's conclusion- Fixation performance differed by fracture type. KW showed favorable performance for type B fractures, whereas screw fixation (CS or FTCS) demonstrated superior performance for type C fractures. IFBM is a theoretical metric that requires clinical validation.
Abstract
BACKGROUND: Optimal fixation for Herscovici type B and type C medial malleolar fractures because of debated due to differences in fragment size and loading conditions. PURPOSE: This study introduces the theoretical concept of Internal Fixation Bone Mass Index (IFBM) and compares three fixation methods under multidirectional loading. STUDY DESIGN: Biomechanical study using Synbone® artificial tibia models. METHODS: Synbone® tibia models simulated type B (small fragment, n=27) and type C (large fragment, n=27) fractures. Three fixation methods-cannulated screws (CS, 4.0 mm), fully threaded cancellous screws (FTCS, 4.0 mm), and Kirschner wires (KW, 1.5 mm)-were tested under axial, transverse, and traction loading using an Instron® 5969 machine. IFBM was defined as A_implant/A_bone. RESULTS: For type B fractures, KW showed a higher 2 mm displacement load under traction than CS (65 ± 11 N vs. 31 ± 9 N; post-hoc p = 0.008) and FTCS (65 ± 11 N vs. 36 ± 12 N; post-hoc p = 0.012), with no statistically significant difference under axial and transverse loading (ANOVA p = 0.231 and p = 0.501). For type C fractures, CS and FTCS showed higher stability than KW under transverse and traction loading (ANOVA p = 0.004 and p = 0.003); no statistically significant difference was detected under axial loading (ANOVA p = 0.167). CONCLUSIONS: Fixation performance differed by fracture type. KW showed favorable performance for type B fractures, whereas screw fixation (CS or FTCS) demonstrated superior performance for type C fractures. IFBM is a theoretical metric that requires clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical efficacy of wire fixation methods for oblique metacarpal shaft fracturesMedicine · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Biomechanical and finite element analysis of a novel annular multi-axial locking plate for patellar fracture fixation.Journal of orthopaedic surgery and research · 2026
- Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fracturesArchives of Orthopaedic and Trauma Surgery · 2026
- Biomechanical evaluation of cerclage fixation constructs in a 3-dimensionally printed canine tibial long-oblique fracture model.American journal of veterinary research · 2026
- Mini Fragment T-Plate Fixation for Medial Malleolar Fractures Achieves Comparable Outcomes to Small Fragment Screw Fixation Without Increased Complication Risk.Journal of orthopaedic trauma · 2026