Evaluation of the crystalline lens diameter using swept-source optical coherence tomography.
Sophia Anna Reifeltshammer, Haidar Khalil, Theresa Höftberger, Peter Laubichler, Leon Pomberger, Klemens Waser, Matthias Bolz, Nino Hirnschall
Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria. · Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Upper Austria, Austria nino.hirnschall@googlemail.com.
Key points
From the paper's conclusion- The crystalline lens diameter followed a normal distribution with no significant differences between short and long eyes. All three models demonstrated low predictive accuracies, suggesting that reliable prediction of eLD is currently not attainable.
Abstract
OBJECTIVE: To evaluate the estimated lens diameter (eLD) of the crystalline lens in a large European cohort. METHODS AND ANALYSIS: Data sets from an Austrian population acquired between 2020 and 2022 were analysed in this study. Measurements included optical biometry (IOLMaster 700, Carl Zeiss Meditec AG, Germany) as well as anterior segment optical coherence tomography (CASIA2, Tomey, Japan). For eLD prediction, three different machine learning approaches were implemented. RESULTS: In total, 2352 eyes of 2352 patients were included in this study. The eLD was normally distributed with a mean value of 10.18±0.56 mm, showing a statistically significant difference (p=0.008) between females and males (10.16±0.54 mm and 10.22±0.57 mm, respectively). There was a low but significant correlation (p<0.01 for all) with age (r=0.246), lens thickness (r=0.265), white-to-white (r=0.122), corneal radii (r=0.090), axial eye length (r=0.092), anterior chamber depth (r=-0.060), decentration (r=-0.087) and tilt (r=-0.159), respectively. Subanalysis of short and long eyes yielded no significant difference in eLD. For eLD prediction, age and lens thickness appeared to be relevant parameters, with all three models demonstrating low predictive accuracy. CONCLUSION: The crystalline lens diameter followed a normal distribution with no significant differences between short and long eyes. All three models demonstrated low predictive accuracies, suggesting that reliable prediction of eLD is currently not attainable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Correlation Between Lens Density and Inter-Method Difference in Axial Length: Sum-of-Segments Versus Traditional Method on a Novel SS-OCT Biometer and the IOLMaster 700.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Analysis of ocular biometrics in cataract patients aged 40 and above in Suzhou, China.Frontiers in medicine · 2026
- Evaluation of axial length measurement and other biometric parameters using three different generations of biometers.Frontiers in medicine · 2026
- Clinical Interchangeability Boundaries of Pentacam AXL WAVE in Preoperative Biometry for Cataract Surgery: An Agreement Study with IOLMaster 700 and Pentacam.Journal of clinical medicine · 2026
- Investigation of ciliary body inner diameter in Chinese myopic adults using ArcScan Insight® 100.Frontiers in medicine · 2026
- Comparison of anterior segment parameters in cataract patients with different axial lengths using IOL Master and Pentacam.BMC ophthalmology · 2026