Investigation of ciliary body inner diameter in Chinese myopic adults using ArcScan Insight® 100.
Lei Luo, Xindi Wang, Qianrong Hu, Yan Cai, Linjuan Yang, Yu Zhang, Shimin Tan, Yimeng Fan,
Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China. · Department of Ophthalmology, Xi'an Ninth Hospital, Xi'an, Shaanxi, China.
Key points
From the paper's conclusion- ArcScan Insight 100 allows direct measurement of CBID using a standardized protocol. In Chinese myopic adults, CBID was normally distributed and was mainly associated with STS. The Reinstein formula, which incorporates CBID, resulted in different ICL size recommendations for half of the eyes compared to the traditional WTW-based method. These findings demonstrate that incorporation of CBID can alter preoperative ICL size recommendations, though its direct effect on postoperative vault prediction requires future surgical validation.
Abstract
BACKGROUND: Ciliary body inner diameter (CBID) was recently reported as a new parameter for Implantable Collamer Lens (ICL) sizing. This study aimed to characterize CBID in Chinese myopic adults using the novel ArcScan Insight 100 very high-frequency ultrasound biomicroscope, identify its associated ocular anatomical factors, and assess its influence on Implantable Collamer Lens (ICL) size recommendations. METHODS: In this cross-sectional study, 107 myopic eyes of 58 Chinese adults were enrolled. Anterior segment parameters, including CBID, were measured using ArcScan Insight 100. Linear mixed-effect models (LMMs) were fitted to identify determinants of CBID while accounting for inter-eye correlation. The relative contributions of independent variables were evaluated using partR2 . ICL sizes calculated via the Reinstein formula (incorporating CBID) were compared with those from the STAAR OCOS formula (based on white-to-white diameter). RESULTS: The mean CBID was 10.80 ± 0.48 (range 9.76 to 11.97) mm. Multivariate LMM analysis revealed that wider CBID was independently associated with younger age (P = 0.045), lower crystalline lens rise (CLR, P = 0.011), wider sulcus-to-sulcus diameter (STS, P < 0.001), and smaller STS lens rise (STSL, P = 0.017). PartR2 analyses identified STS (partR² = 0.595) as the dominant contributor, explaining 59.5% of CBID variability. ICL sizes recommended by the Reinstein formula differed significantly from OCOS-based sizes (F = 4.672, P = 0.010), with 49% agreement. CONCLUSIONS: ArcScan Insight 100 allows direct measurement of CBID using a standardized protocol. In Chinese myopic adults, CBID was normally distributed and was mainly associated with STS. The Reinstein formula, which incorporates CBID, resulted in different ICL size recommendations for half of the eyes compared to the traditional WTW-based method. These findings demonstrate that incorporation of CBID can alter preoperative ICL size recommendations, though its direct effect on postoperative vault prediction requires future surgical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Ciliary Body Imaging Using Image-Registered Swept-Source AS-OCT and Ultrasound Biomicroscopy.Translational vision science & technology · 2026
- Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas.Acta ophthalmologica · 2026
- Influencing Factors of Positional Stability of Implantable Collamer Lenses in Terms of Rotation, Decentration, and Tilt in Patients With Myopia.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Risk Factors Associated With ICL Decentration After ICL Surgery.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Assessment of Chord Mu and Chord Alpha in Relation to Post-ICL Implantation Visual Quality.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Development and Clinical Evaluation of an Anterior Chamber Angle-Based Lens Sizing Method for Implantable Collamer Lens Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2026