From Earlier to Updated Quadrifocal Intraocular Lens Designs: An Objective Optical Metrology Analysis.
Eun Ah Jeong, Seung Pil Bang, Seth Pantanelli, Su Jin Kang, Sonia H Yoo
Department of Ophthalmology, Keimyung University School of Medicine, Daegu, Republic of Korea. · Department of Ophthalmology, Penn State College of Medicine, Hershey, PA, USA.
Key points
From the paper's conclusion- The PanOptix Pro preserves the fundamental design and spherical aberration profile of the original PanOptix, while showing localized diffractive step-height modifications. Together with clearer far-intermediate F-image preservation, sustained central PSF-core brightness, and a shallower post-peak aMTF dip, these findings are consistent with a relative redistribution of optical energy toward the far-intermediate region, supporting greater far-intermediate optical continuity without substantial changes in nominal add power or overall focal structure.
Abstract
PURPOSE: To compare the optical performance of the Clareon PanOptix and Clareon PanOptix Pro intraocular lenses (IOLs) using interferometric metrology and identify measurable optical differences. SETTING: Physiological Optics Laboratory, Daegu, Republic of Korea. DESIGN: Experimental optical-bench investigation. METHODS: Three +20.0 D samples each of the PanOptix and PanOptix Pro IOLs (Alcon) were analyzed using a Mach-Zehnder interferometer in a model eye incorporating +0.27 µm corneal spherical aberration. Microscopic imaging, wavefront reconstruction with Zernike analysis, diffractive-step profile reconstruction, point-spread function (PSF)-based retinal image simulation, halo analysis, and through-focus modulation transfer function (TF-MTF) analysis were performed. RESULTS: Both IOLs showed broadly similar diffractive architecture and spherical aberration profiles. Peak-to-valley step-profile amplitudes were comparable, although the PanOptix Pro showed localized differences in the reconstructed step-height contour. PSF-based analyses showed broadly similar focal behavior, but the PanOptix Pro demonstrated clearer Sloan F contour preservation and more evident central PSF-core brightness at the far-intermediate position. In through-focus average MTF (aMTF) profiles, the PanOptix Pro showed a modestly higher far-focus peak and a less pronounced post-peak dip, particularly at 4.5- and 3.0-mm pupils. MTF50 analysis showed a similar overall pattern, with greater variability and more apparent inter-model differences at larger pupil sizes. CONCLUSIONS: The PanOptix Pro preserves the fundamental design and spherical aberration profile of the original PanOptix, while showing localized diffractive step-height modifications. Together with clearer far-intermediate F-image preservation, sustained central PSF-core brightness, and a shallower post-peak aMTF dip, these findings are consistent with a relative redistribution of optical energy toward the far-intermediate region, supporting greater far-intermediate optical continuity without substantial changes in nominal add power or overall focal structure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Interferometric analysis of diffractive multifocal intraocular lenses.Journal of cataract and refractive surgery · 2026
- Comparative Optical Performance of Two Enhanced Monofocal IOLs Across Pupil Sizes and Lens Powers.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- In Vitro Optical Bench Assessment of an Extended Depth-of-Focus Intraocular Lens Based on Segmented Refractive Design.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Fabrication and in vitro optical characterization of a diffractive trifocal intraocular lens with step heights modulated by a cosine function.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Straylight-Based Evaluation of Glare in Two Presbyopia-Correcting Intraocular Lenses.Klinische Monatsblatter fur Augenheilkunde · 2026
- Visual Performance of a Novel Intraocular Lens With Higher-Order Aspheric Design Optimized for Intermediate Vision.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026